XCSLE Series, Interlock Switches

Results:
19
Manufacturer
Series
Circuit
Ingress Protection
Termination Style
Conduit Thread Size
Holding Force
Voltage Rating
Approval Agency
Current Rating (Amps)
Type
Operating Temperature
Must Release
Must Operate
Actuator Type
Voltage - Supply
Features
Results remaining19
Applied Filters:
XCSLE
Select
ImageProduct DetailPriceAvailabilityECAD ModelCircuitFeaturesOperating TemperatureTermination StyleMust OperateMust ReleaseApproval AgencyActuator TypeIngress ProtectionTypeHolding ForceVoltage - SupplyConduit Thread SizeSeriesVoltage RatingCurrent Rating (Amps)
XCSLE2525312
PLAS INTER, LOCK W/O POWER, 24 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66 - Dust Tight, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2727313
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
-25°C ~ 60°C
Screw Terminal
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Solenoid Locking
143kgf
-
1/2" NPT
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2727312
PLAS INTER, LOCK W/O POWER, 24 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3535312
PLAS INTER, LOCK W/O POWER, 24 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2727512
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
-25°C ~ 60°C
Screw Terminal
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Solenoid Locking
143kgf
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3737312
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-1NO/2NC
-
-25°C ~ 60°C
Screw Terminal
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Solenoid Locking
143kgf
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE373731M3
PLAS INTLK W/ POWR, 24 VAC/DC, 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
-25°C ~ 60°C
Connector
-
-
CSA, TUV, UL
Panel Disconnect
IP65 - Dust Tight, Water Resistant
Key Locking
-
-
-
XCSLE
24VAC, 24VDC
1.5A (AC), 220mA (DC)
XCSLE2525332
PLAS INTER, LOCK W/O POWER, 120
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3535342
PLAS INTER, LOCK W/O POWER, 240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE353531M3
PLAS INTLK W/ POWR, 24 VAC/DC, 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
-25°C ~ 60°C
Connector
-
-
CSA, UL
Panel Disconnect
IP65 - Dust Tight, Water Resistant
Key Locking
-
-
-
XCSLE
24VAC, 24VDC
1.5A (AC), 220mA (DC)
XCSLE2525342
PLAS INTER, LOCK W/O POWER, 240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, UL
Panel Disconnect
IP66 - Dust Tight, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2727332
PLAS INTER, LOCK W/O POWER, 120
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2525512
PLAS INTER, LOCK W/ POWER, 24 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3838342
PLAS INTER, LOCK W/O POWER, 240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3737342
PLAS INTER, LOCK W/O POWER, 240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3737512
PLAS INTER, LOCK W/O POWER, 24 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
24VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2727333
SAFETY INTLK, PLASTIC, LOCKING W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
1/2" NPT
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE2525513
SAFETY INTLK, PLASTIC, LOCKING W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, TUV, UL
Panel Disconnect
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Key Locking
-
-
1/2" NPT
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)
XCSLE3838312
PLAS INTER, LOCK W/O POWER, 24 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-NC
-
-25°C ~ 60°C
Cable Leads
-
-
CSA, UL
Panel Disconnect
IP66 - Dust Tight, Waterproof
Key Locking
-
-
M20 x 1.5
XCSLE
240VAC, 24VDC
750mA (AC), 550mA (DC)

About  Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.