Fuses

Results:
25,689
Filters
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesColorMounting TypeVoltage Rating - ACCurrent Rating (Amps)Operating TemperaturePackage / CaseApproval AgencyResponse TimeFuse TypeVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
1206SFS100F/63-2
FUSE BOARD MOUNT 1A 63VDC 1206
1+
$0.0521
5+
$0.0486
10+
$0.0451
Quantity
1,474,234 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SFS
-
Surface Mount
-
1 A
-55°C ~ 125°C
1206 (3216 Metric)
UL
Slow Blow
Board Mount (Cartridge Style Excluded)
63 V
50A
0.11
0.126" L x 0.063" W x 0.038" H (3.20mm x 1.60mm x 0.97mm)
0402SFF400F/24-2
FUSE BOARD MOUNT 4A 24VDC 0402
1+
$0.0313
5+
$0.0292
10+
$0.0271
Quantity
899,636 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SFF
-
Surface Mount
-
4 A
-55°C ~ 125°C
0402 (1005 Metric)
UL
Fast Blow
Board Mount (Cartridge Style Excluded)
24 V
35A
0.225
0.039" L x 0.020" W x 0.020" H (1.00mm x 0.51mm x 0.51mm)
1206SFF200F/63-2
FUSE BOARD MOUNT 2A 63VDC 1206
1+
$0.0833
5+
$0.0778
10+
$0.0722
Quantity
833,191 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SFF
-
Surface Mount
-
2 A
-55°C ~ 125°C
1206 (3216 Metric)
UL
Fast Blow
Board Mount (Cartridge Style Excluded)
63 V
50A
0.07
0.126" L x 0.063" W x 0.043" H (3.20mm x 1.60mm x 1.10mm)
0697H9150-02
FUSE BRD MNT 15A 350VAC 72VDC
1+
$0.3125
5+
$0.2917
10+
$0.2708
Quantity
800,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
0697H
-
Through Hole
350 V
15 A
-55°C ~ 125°C
Radial, Box
AEC-Q200, cURus
Slow Blow
Board Mount (Cartridge Style Excluded)
72 V
150A AC, 200A DC
563
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0467.500NRHF
FUSE BOARD MOUNT 500MA 32VAC/VDC
1+
$0.0229
5+
$0.0214
10+
$0.0199
Quantity
770,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
467
-
Surface Mount
32 V
500 mA
-55°C ~ 90°C
0603 (1608 Metric)
CSA, UL
Fast Blow
Board Mount (Cartridge Style Excluded)
32 V
50A
0.0087
0.063" L x 0.032" W x 0.012" H (1.60mm x 0.81mm x 0.31mm)
0467005.NRHF
FUSE BOARD MNT 5A 32VAC/VDC 0603
1+
$0.0250
5+
$0.0233
10+
$0.0217
Quantity
642,068 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
467
-
Surface Mount
32 V
5 A
-55°C ~ 90°C
0603 (1608 Metric)
CSA, UL
Fast Blow
Board Mount (Cartridge Style Excluded)
32 V
35A
0.9
0.063" L x 0.032" W x 0.012" H (1.60mm x 0.81mm x 0.31mm)
0466.750NRHF
FUSE BOARD MOUNT 750MA 63VAC/VDC
1+
$0.0417
5+
$0.0389
10+
$0.0361
Quantity
351,357 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SlimLine™ 466
-
Surface Mount
63 V
750 mA
-55°C ~ 90°C
1206 (3216 Metric)
CSA, UL
Fast Blow
Board Mount (Cartridge Style Excluded)
63 V
50A
0.0276
0.125" L x 0.060" W x 0.023" H (3.18mm x 1.52mm x 0.58mm)
046701.5NR
FUSE BOARD MNT 1.5A 32VAC 65VDC
1+
$0.0417
5+
$0.0389
10+
$0.0361
Quantity
313,448 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
467
-
Surface Mount
32 V
1.5 A
-55°C ~ 90°C
0603 (1608 Metric)
CSA, UL
Fast Blow
Board Mount (Cartridge Style Excluded)
65 V
35A AC, 13A DC
0.0766
0.063" L x 0.032" W x 0.012" H (1.60mm x 0.81mm x 0.31mm)
0217005.MXP
FUSE GLASS 5A 250VAC 5X20MM
1+
$0.0521
5+
$0.0486
10+
$0.0451
Quantity
311,691 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
217
-
Requires Holder
250 V
5 A
-55°C ~ 125°C
5mm x 20mm
BSI, CE, CCC, CSA, KC, PSE, SEMKO, UR, VDE
Fast Blow
Cartridge, Glass
-
50A
42.795
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
3403.0176.24
FUSE BOARD MNT 10A 250VAC 125VDC
1+
$0.7500
5+
$0.7000
10+
$0.6500
Quantity
300,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
UMT 250
-
Surface Mount
250 V
10 A
-55°C ~ 125°C
2-SMD, Square End Block
cURus, PSE/JET
Slow Blow
Board Mount (Cartridge Style Excluded)
125 V
35A
166
0.398" L x 0.118" W x 0.118" H (10.10mm x 3.00mm x 3.00mm)
0469005.WR
FUSE BOARD MOUNT 5A 32VDC 1206
1+
$0.2083
5+
$0.1944
10+
$0.1806
Quantity
260,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
469
-
Surface Mount
-
5 A
-55°C ~ 150°C
1206 (3216 Metric)
CSA, UL
Slow Blow
Board Mount (Cartridge Style Excluded)
32 V
60A
5.62
0.129" L x 0.064" W x 0.035" H (3.27mm x 1.63mm x 0.90mm)
0239003.MXP
FUSE GLASS 3A 250VAC 5X20MM
1+
$0.1667
5+
$0.1556
10+
$0.1444
Quantity
232,928 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
239
-
Requires Holder
250 V
3 A
-55°C ~ 125°C
5mm x 20mm
CE, CSA, KC, PSE, UL
Slow Blow
Cartridge, Glass
-
100A
129.51
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
0466.125NRHF
FUSE BOARD MNT 125MA 125VAC/VDC
1+
$0.0354
5+
$0.0331
10+
$0.0307
Quantity
214,710 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SlimLine™ 466
-
Surface Mount
125 V
125 mA
-55°C ~ 90°C
1206 (3216 Metric)
CSA, UL
Fast Blow
Board Mount (Cartridge Style Excluded)
125 V
50A
0.0004
0.125" L x 0.060" W x 0.023" H (3.18mm x 1.52mm x 0.58mm)
0452002.MRL
FUSE BOARD MNT 2A 125VAC/VDC SMD
1+
$0.0750
5+
$0.0700
10+
$0.0650
Quantity
175,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
NANO²® 452
-
Surface Mount
125 V
2 A
-55°C ~ 125°C
2-SMD, Square End Block
CSA, PSE, UR
Slow Blow
Board Mount (Cartridge Style Excluded)
125 V
50A
8.2
0.240" L x 0.106" W x 0.106" H (6.10mm x 2.69mm x 2.69mm)
0468003.NRHF
FUSE BOARD MNT 3A 32VAC/VDC 1206
1+
$0.0313
5+
$0.0292
10+
$0.0271
Quantity
170,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
SlimLine™ 468
-
Surface Mount
32 V
3 A
-55°C ~ 90°C
1206 (3216 Metric)
CSA, UL
Slow Blow
Board Mount (Cartridge Style Excluded)
32 V
50A
1.27
0.125" L x 0.060" W x 0.023" H (3.18mm x 1.52mm x 0.58mm)
0297015.WXNV
FUSE AUTO 15A 32VDC BLADE MINI
1+
$0.0375
5+
$0.0350
10+
$0.0325
Quantity
159,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
MINI® 297
Blue
Requires Holder
-
15 A
-40°C ~ 125°C
Blade, Miniature
-
Fast Blow
Automotive
32 V
1kA
270
0.429" L x 0.150" W x 0.346" H (10.90mm x 3.80mm x 8.80mm)
0287040.PXCN
FUSE AUTOMOTIVE 40A 32VDC BLADE
1+
$0.0354
5+
$0.0331
10+
$0.0307
Quantity
151,923 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
ATOF®
Orange
Requires Holder
-
40 A
-40°C ~ 105°C
Blade, ATO/ATC
CSA, UL
-
Automotive
32 V
-
3310
0.752" L x 0.201" W x 0.484" H (19.10mm x 5.10mm x 12.30mm)
0452.750MRL
FUSE BOARD MNT 750MA 125VAC/VDC
1+
$0.1146
5+
$0.1069
10+
$0.0993
Quantity
145,094 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
NANO²® 452
-
Surface Mount
125 V
750 mA
-55°C ~ 125°C
2-SMD, Square End Block
CSA, UR
Slow Blow
Board Mount (Cartridge Style Excluded)
125 V
50A
0.904
0.240" L x 0.106" W x 0.106" H (6.10mm x 2.69mm x 2.69mm)
0877004.MRET1P
FUSE CERAMIC 4A 250VAC AXIAL
1+
$0.5417
5+
$0.5056
10+
$0.4694
Quantity
145,000 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
877
-
Through Hole
250 V
4 A
-55°C ~ 125°C
Cartridge, Non-Standard (Axial)
cULus, VDE
Slow Blow
Cartridge, Ceramic
-
40A
143.4
0.142" Dia x 0.394" L (3.60mm x 10.00mm)
39214000000
FUSE BOARD MOUNT 4A 250VAC RAD
1+
$0.0250
5+
$0.0233
10+
$0.0217
Quantity
142,800 Available
Can ship immediately
PCB Symbol, Footprint & 3D Model
TE5® 392
-
Through Hole
250 V
4 A
-40°C ~ 125°C
Radial, Box
CQC, cULus, KC, PSE/JET, SEMKO, VDE
Slow Blow
Board Mount (Cartridge Style Excluded)
-
40A
100
0.335" L x 0.157" W x 0.315" H (8.50mm x 4.00mm x 8.00mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.