Gas Discharge Tube Arresters (GDT)

Results:
4,345
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Package / Case
Impulse Discharge Current (8/20µs)
Tolerance
Mounting Type
Number of Poles
Fail Short
Voltage - Continuous Operating (Max) (MCOV)
Operating Temperature
Form
Approval Agency
Voltage - Protection Rating (VPR)
Current - Discharge (Max) (8/20µS)
Current - Discharge (Nom) (8/20µS)
Type
Voltage - Protection Level (VP) (2416)
Current - Short Circuit Rating (SCRR)
Features
Results remaining4,345
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTolerancePackage / CaseNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail Short
B88069X9231T203
GDT 90V 2KA 2 POLE SURFACE MOUNT
1+
$1.2676
5+
$1.1972
10+
$1.1268
Quantity
212,095 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±30%
1812 (4532 Metric)
2
S30-A90X
90 V
2000A (2kA)
No
B88069X4211T902
GDT 300V 2.5KA 2 POLE SMD
1+
$0.3803
5+
$0.3592
10+
$0.3380
Quantity
130,400 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±15%
2-SMD Cylinder Square End
2
ES
300 V
2500A (2.5kA)
No
2035-09-SM-RPLF
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.4183
5+
$0.3951
10+
$0.3718
Quantity
79,500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2-SMD Cylinder Square End
2
2035-SM
90 V
5000A (5kA)
No
B88069X9800B502
GDT 230V 10KA 3 POLE TH
1+
$0.8366
5+
$0.7901
10+
$0.7437
Quantity
63,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
T33
230 V
10000A (10kA)
No
B88069X2880S102
GDT 600V 20KA 2 POLE TH
1+
$0.4563
5+
$0.4310
10+
$0.4056
Quantity
50,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
A81
600 V
20000A (20kA)
No
B88069X1640T902
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.1521
5+
$0.1437
10+
$0.1352
Quantity
40,500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2-SMD Cylinder Square End
2
M50
90 V
5000A (5kA)
No
2026-09-C2LF
GDT 90V 20KA 3 POLE THROUGH HOLE
1+
$3.0423
5+
$2.8732
10+
$2.7042
Quantity
36,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
TRIGARD® 2026
90 V
20000A (20kA)
No
B88069X8300B502
GDT 90V 10KA 3 POLE THROUGH HOLE
1+
$0.5070
5+
$0.4789
10+
$0.4507
Quantity
32,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
T83
90 V
10000A (10kA)
No
SL1002A350SM
GDT 350V 5KA 2 POLE SMD
1+
$0.4563
5+
$0.4310
10+
$0.4056
Quantity
27,054 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2-SMD Cylinder Square End
2
SL1002A
350 V
5000A (5kA)
No
B88069X4651S102
GDT 1000V 2KA 2 POLE TH
1+
$0.7606
5+
$0.7183
10+
$0.6761
Quantity
21,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EM
1000 V
2000A (2kA)
No
SL1003A090R
GDT 90V 10KA 3 POLE THROUGH HOLE
1+
$0.8873
5+
$0.8380
10+
$0.7887
Quantity
15,130 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
Axial Cylinder, 3 Lead (Radial Bend)
3
SL1003A
90 V
10000A (10kA)
No
2035-35-SM-RPLF
GDT 350V 5KA 2 POLE SMD
1+
$0.4056
5+
$0.3831
10+
$0.3606
Quantity
14,574 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±15%
2-SMD Cylinder Square End
2
2035-SM
350 V
5000A (5kA)
No
2035-09-BT1LF
GDT 90V 5KA 2 POLE THROUGH HOLE
1+
$0.7606
5+
$0.7183
10+
$0.6761
Quantity
14,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
2035
90 V
5000A (5kA)
No
B88069X2311S102
GDT 3600V 2KA 2 POLE TH
1+
$0.5577
5+
$0.5268
10+
$0.4958
Quantity
12,165 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EM
3600 V
2000A (2kA)
No
B88069X0180S102
GDT 75V 5KA 2 POLE THROUGH HOLE
1+
$1.7113
5+
$1.6162
10+
$1.5211
Quantity
11,638 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EC
75 V
5000A (5kA)
No
SL1002A090SM
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.3803
5+
$0.3592
10+
$0.3380
Quantity
10,478 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2-SMD Cylinder Square End
2
SL1002A
90 V
5000A (5kA)
No
GTCS35-750M-R05-2
GDT 75V 5KA 3 POLE SURFACE MOUNT
1+
$1.1408
5+
$1.0775
10+
$1.0141
Quantity
10,089 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
3-SMD Cylinder Square End
3
GT
75 V
5000A (5kA)
No
B88069X2140S102
GDT 800V 10KA 2 POLE TH
1+
$2.1854
5+
$2.0639
10+
$1.9425
Quantity
10,070 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±15%
Axial Cylinder
2
A71
800 V
10000A (10kA)
No
2051-15-SM-RPLF
GDT 150V 2KA 2 POLE SMD
1+
$0.6338
5+
$0.5986
10+
$0.5634
Quantity
9,922 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±30%
1812 (4532 Metric)
2
2051
150 V
2000A (2kA)
No
2017-09-SMC-RPLF
GDT 90V 10KA 2 POLE SMD VERTICAL
1+
$1.5211
5+
$1.4366
10+
$1.3521
Quantity
8,350 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount Vertical
±20%
Disc 8.00mm Tabbed SMD
2
2017
90 V
10000A (10kA)
No

Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.