PXS Series, Interlock Switches

Results:
8
Filters
Applied Filters:
PXS
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesCircuitOperating TemperatureVoltage - SupplyTermination StyleApproval AgencyCurrent Rating (Amps)Ingress ProtectionFeaturesVoltage RatingTypeHolding ForceActuator TypeMust OperateMust ReleaseConduit Thread Size
PXS59150
SAFETY SENSOR NO + NC/CABLE 5M/L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NO/NC
-25°C ~ 85°C
24VDC
Cable Leads
CE, cURus
100mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Status Indicator
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS79020
SAFETY SENSOR 2NO/CABLE 2M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NC
-25°C ~ 85°C
-
Cable Leads
CE, cURus
10mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS70150
SAFETY SENSOR 2NO+NC/CABLE 5M/LE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
3PST-2NC/1NO
-25°C ~ 85°C
24VDC
Cable Leads
CE, cURus
10mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Status Indicator
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS79150
SAFETY SENSOR 2NO/CABLE 5M/LED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NC
-25°C ~ 85°C
24VDC
Cable Leads
CE, cURus
10mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
Status Indicator
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS59010
SAFETY SENSOR NO+NC/CABLE 10M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NO/NC
-25°C ~ 85°C
-
Cable Leads
CE, cURus
100mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS79010
SAFETY SENSOR 2NO/CABLE 10M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NC
-25°C ~ 85°C
-
Cable Leads
CE, cURus
10mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS10350
SAFETY SENSOR 2NO+NC/CABLE 5M/SA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
3PST-2NC/1NO
-25°C ~ 85°C
-
Cable Leads
CE
100mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-
PXS79050
SAFETY SENSOR 2NO/CABLE 5M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
PXS
DPST-NC
-25°C ~ 85°C
-
Cable Leads
CE, cURus
10mA (DC)
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-
24VDC
Magnetic
-
Non-Contact
8mm
20mm
-

About  Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.