D41L Series, Interlock Switches

Results:
10
Manufacturer
Series
Type
Operating Temperature
Must Release
Holding Force
Must Operate
Ingress Protection
Termination Style
Voltage Rating
Actuator Type
Approval Agency
Current Rating (Amps)
Conduit Thread Size
Circuit
Voltage - Supply
Features
Results remaining10
Applied Filters:
D41L
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureVoltage - SupplyCircuitApproval AgencyFeaturesMust OperateMust ReleaseTermination StyleCurrent Rating (Amps)Actuator TypeIngress ProtectionVoltage RatingSeriesTypeHolding ForceConduit Thread Size
D41L1YDAN2
D41L SENSOR, D41L-1YDA-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Release
117kgf
-
D41L2YDAEN2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Release
117kgf
-
D41L2ZDGEN2
D41L SENSOR, D41L-2ZDGE-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Locking
117kgf
-
D41L1ZDGN2
D41L SENSOR, D41L-1ZDG-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Locking
117kgf
-
D41L1ZDAN2
D41L SENSOR, D41L-1ZDA-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Release
117kgf
-
D41L2YDAN2
D41L SENSOR, D41L-2YDA-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Release
117kgf
-
D41L2ZDAN2
D41L SENSOR, D41L-2ZDA-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Release
117kgf
-
D41L2YDGN2
D41L SENSOR, D41L-2YDG-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Locking
117kgf
-
D41L1YDGN2
D41L SENSOR, D41L-1YDG-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Locking
117kgf
-
D41L2ZDGN2
D41L SENSOR, D41L-2ZDG-N2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
0°C ~ 60°C
24VDC
-
CE, cULus
Manual Override
-
-
Connector (M12)
250mA (DC)
Panel Disconnect
IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
24VDC
D41L
RFID, Solenoid Locking
117kgf
-

About  Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.