SMS Series, Interlock Switches

Results:
11
Filters
Applied Filters:
SMS
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesFeaturesIngress ProtectionOperating TemperatureTermination StyleApproval AgencyVoltage RatingCircuitVoltage - SupplyTypeCurrent Rating (Amps)Holding ForceActuator TypeMust OperateMust ReleaseConduit Thread Size
SMSA2P10
14130876 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
SPST-NO
100VAC
Magnetic
250mA (AC)
-
Non-Contact
16mm
20mm
-
SMSA2P02
14130775 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO/NC
100VAC
Magnetic
250mA (AC)
-
Non-Contact
15mm
20mm
-
SMSA2P03
14150272 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
CE
-
4PST-2NO/2NC
100VAC
Magnetic
250mA (AC)
-
Non-Contact
16mm
20mm
-
SMS02
14117742 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO/NC
100VAC
Magnetic
250mA (AC)
-
Non-Contact
10mm
15mm
-
SMS01
14117641 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO/NC
100VAC
Magnetic
250mA (AC)
-
Non-Contact
10mm
15mm
-
SMS02LD
14147144 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Status Indicator
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO/NC
120VAC, 50VDC
Magnetic
100mA (AC), 250mA (DC)
-
Non-Contact
20mm
30mm
-
SMS02S1
14135323 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO/NC
120VAC, 50VDC
Magnetic
100mA (AC), 250mA (DC)
-
Non-Contact
20mm
30mm
-
SMS03
14120469 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
DPST-NO
100VAC
Magnetic
250mA (AC)
-
Non-Contact
20mm
22mm
-
SMS03+CM1A4/03MT
14127038 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
-
-
DPST-NO
100VAC
Magnetic
250mA (AC)
-
Non-Contact
20mm
22mm
-
SMSAP20AF03DCP
14154215 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
CE, UL
-
DPST-NO
120VAC, 50VDC
Magnetic
100mA (AC), 250mA (DC)
-
Non-Contact
20mm
22mm
-
SMS03NC
14135222 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
-
-
3PST-2NO/1NC
100VAC
Magnetic
250mA (AC)
-
Non-Contact
20mm
22mm
-

About  Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.