0697H Series, Fuses

Results:
64
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Results remaining64
Applied Filters:
0697H
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperatureResponse TimeCurrent Rating (Amps)Package / CaseSeriesFuse TypeVoltage Rating - ACVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / Dimension
0697H9150-02
FUSE BRD MNT 15A 350VAC 72VDC
1+
$0.3549
5+
$0.3352
10+
$0.3155
Quantity
26,101 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
15 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
563
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H6300-05
FUSE BRD MNT 6.3A 350VAC 72VDC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
6.3 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
180
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H0315-05
FUSE BRD MNT 315MA 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
315 mA
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
0.27
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H8000-02
FUSE BRD MNT 8A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
8 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
325
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9100-05
FUSE BRD MNT 10A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
10 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
370
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9200-01
FUSE BRD MNT 20A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
20 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
1100
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H0400-05
FUSE BRD MNT 400MA 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
400 mA
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
0.57
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H1600-05
FUSE BRD MNT 1.6A 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
1.6 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
13
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H0500-05
FUSE BRD MNT 500MA 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
500 mA
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
1.1
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H2500-01
FUSE BRD MNT 2.5A 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
2.5 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
35
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9120-05
FUSE BRD MNT 12A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
12 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
360
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H8000-05
FUSE BRD MNT 8A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
8 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
325
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9200-05
FUSE BRD MNT 20A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
20 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
1100
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H8000-01
FUSE BRD MNT 8A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
8 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
325
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9150-01
FUSE BRD MNT 15A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
15 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
563
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H5000-01
FUSE BRD MNT 5A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
5 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
130
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H9160-01
FUSE BRD MNT 16A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
16 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
610
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H2000-05
FUSE BRD MNT 2A 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
2 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
23
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H4000-01
FUSE BRD MNT 4A 350VAC 72VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
4 A
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
72 V
150A AC, 200A DC
85
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)
0697H0800-01
FUSE BRD MNT 800MA 350VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Slow Blow
800 mA
Radial, Box
0697H
Board Mount (Cartridge Style Excluded)
350 V
100 V
100A AC, 65A DC
3.6
AEC-Q200, cURus
0.329" L x 0.157" W x 0.307" H (8.35mm x 4.00mm x 7.80mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.