BSPM Series, Surge Protection Devices (SPDs)

Results:
84
Manufacturer
Series
Voltage - Continuous Operating (Max) (MCOV)
Voltage - Protection Level (VP) (2416)
Approval Agency
Number of Poles
Voltage - Protection Rating (VPR)
Current - Short Circuit Rating (SCRR)
Features
Current - Discharge (Max) (8/20µS)
Current - Discharge (Nom) (8/20µS)
Operating Temperature
Form
Type
Mounting Type
Results remaining84
Applied Filters:
BSPM
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureMounting TypeApproval AgencyNumber of PolesSeriesTypeFormVoltage - Continuous Operating (Max) (MCOV)Current - Discharge (Nom) (8/20µS)Current - Discharge (Max) (8/20µS)Current - Short Circuit Rating (SCRR)Voltage - Protection Level (VP) (2416)FeaturesVoltage - Protection Rating (VPR)
BSPM11000WER
VARISTOR 1KV 30KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
-
1
BSPM
Type 2
Base + Module
1kVAC
15 kA
30 kA
25 kA
4.2 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1347S2G
VARISTOR 40KA MODULE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, UL
1
BSPM
Type 2
Base + Module
600VAC
20 kA
40 kA
125 kA
-
Thermally Protected
2 kV
BSPM1347S2GR
VARISTOR 40KA MODULE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, UL
1
BSPM
Type 2
Base + Module
600VAC
20 kA
40 kA
125 kA
-
Remote Signaling Contacts, Thermally Protected
2 kV
BSPM1385TNR
VARISTOR 230V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
385VAC
20 kA
40 kA
25 kA
1.75 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1400WER
VARISTOR 400V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
440VAC
20 kA
40 kA
25 kA
2 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1440TNR
VARISTOR 400V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
440VAC
20 kA
40 kA
25 kA
2 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1600TNR
VARISTOR 480V 30KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
600VAC
15 kA
30 kA
25 kA
2.5 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM11000WE
VARISTOR 1KV 30KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
-
1
BSPM
Type 2
Base + Module
1kVAC
15 kA
30 kA
25 kA
4.2 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1120S2GR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, UL
1
BSPM
Type 2
Base + Module
275VAC
20 kA
40 kA
200 kA
-
Remote Signaling Contacts, Thermally Protected
1 kV
BSPM1240S2G
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, UL
1
BSPM
Type 2
Base + Module
385VAC
20 kA
40 kA
200 kA
-
Thermally Protected
1.5 kV
BSPM1275TN
VARISTOR 230V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
275VAC
20 kA
40 kA
50 kA
1.5 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM1320TN
VARISTOR 230V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, CSA, KEMA
1
BSPM
Type 2
Base + Module
320VAC
20 kA
40 kA
25 kA
1.5 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM2230WE
VARISTOR 230V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, KEMA
2
BSPM
Type 2
Base + Module
275VAC
20 kA
40 kA
50 kA
1.5 kV
Thermally Protected
-
BSPM3208WYG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
ATEX, UL
3
BSPM
Type 2
Base + Module
550VAC
20 kA
40 kA
200 kA
-
Thermally Protected
1.8 kV
BSPM3208WYGR
VARISTOR 208V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
ATEX, UL
3
BSPM
Type 2
Base + Module
550VAC
20 kA
40 kA
200 kA
-
Remote Signaling Contacts, Thermally Protected
1.8 kV
BSPM3240DLGR
VARISTOR 240V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
CE, cURus, UL
3
BSPM
Type 2
Base + Module
550VAC
20 kA
40 kA
200 kA
-
Remote Signaling Contacts, Thermally Protected
1.8 kV
BSPM3275TNCR
VARISTOR 40KA MODULE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, KEMA
3
BSPM
Type 2
Base + Module
275VAC
20 kA
40 kA
50 kA
1.5 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM3385TNC
VARISTOR 40KA MODULE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, KEMA
3
BSPM
Type 2
Base + Module
385VAC
20 kA
40 kA
25 kA
1.75 kV
Thermally Protected
-
BSPM3385TNCR
VARISTOR 40KA MODULE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, KEMA
3
BSPM
Type 2
Base + Module
385VAC
20 kA
40 kA
25 kA
1.75 kV
Remote Signaling Contacts, Thermally Protected
-
BSPM3400WE
VARISTOR 400V 40KA MOD PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-40°C ~ 80°C
DIN Rail
CE, KEMA
3
BSPM
Type 2
Base + Module
440VAC
20 kA
40 kA
25 kA
2 kV
Thermally Protected
-

About  Surge Protection Devices (SPDs)

Surge Protection Devices (SPDs) are both designed to protect electronic systems from voltage surges or transients, but they serve different purposes and operate in distinct ways. TVS diodes are semiconductor devices that are specifically designed to suppress transient voltage spikes by limiting or clamping the voltage at a specific level. They provide protection by diverting excess current away from sensitive components and can respond quickly to voltage spikes. TVS diodes are typically used at the circuit level to protect individual components or small groups of components within electronic devices. On the other hand, Surge Protection Devices (SPDs) are designed to protect entire electrical and electronic systems from temporary power surges or transients on AC or DC power lines. These surges can result from lightning strikes, switching operations, or other electrical disturbances. SPDs are installed at the point of entry of power lines into a building or within individual electrical circuits to safeguard connected equipment from potential damage caused by overvoltage. While TVS diodes are focused on protecting specific components from transient events, SPDs are geared towards safeguarding entire systems from power surges. SPDs utilize a combination of protective components such as metal oxide varistors (MOVs), gas discharge tubes (GDTs), or silicon avalanche diodes (SADs) to absorb and dissipate excessive energy generated during a surge event. In summary, TVS diodes and SPDs both play crucial roles in protecting electronic systems from voltage surges, but they operate at different levels of the system. TVS diodes are used to protect individual components within electronic circuits, while SPDs are employed to safeguard entire electrical and electronic systems from power surges on AC or DC power lines.