1250 Series, Surge Protection Devices (SPDs)

Results:
14
Manufacturer
Series
Voltage - Continuous Operating (Max) (MCOV)
Voltage - Protection Rating (VPR)
Voltage - Protection Level (VP) (2416)
Number of Poles
Operating Temperature
Form
Approval Agency
Mounting Type
Current - Discharge (Max) (8/20µS)
Current - Discharge (Nom) (8/20µS)
Type
Current - Short Circuit Rating (SCRR)
Features
Results remaining14
Applied Filters:
1250
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeOperating TemperatureNumber of PolesSeriesTypeFormVoltage - Continuous Operating (Max) (MCOV)Current - Discharge (Nom) (8/20µS)Current - Discharge (Max) (8/20µS)Current - Short Circuit Rating (SCRR)Voltage - Protection Rating (VPR)Voltage - Protection Level (VP) (2416)FeaturesApproval Agency
1250-1S-480
SPD AC 1W+G 600VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
1
1250
Type 2, Type 4
Base + Module
550VAC
20 kA
50 kA
100 kA
1.8 kV
2.5 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-3S-230
SPD AC 3W+G 230VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
3
1250
Type 2, Type 4
Base + Module
275VAC
20 kA
50 kA
100 kA
1 kV
1.25 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-3S-480
SPD AC 3W+G 600VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
3
1250
Type 2, Type 4
Base + Module
550VAC
20 kA
50 kA
100 kA
1.8 kV
2.5 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-3S-120
SPD AC 3W+G 120VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
3
1250
Type 2, Type 4
Base + Module
150VAC
20 kA
50 kA
100 kA
700 V
900 V
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-4S-120
SPD AC 4W+G 120VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
4
1250
Type 2, Type 4
Base + Module
150VAC
20 kA
50 kA
100 kA
700 V
900 V
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-4S-230
SPD AC 4W+G 230VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
4
1250
Type 2, Type 4
Base + Module
275VAC
20 kA
50 kA
100 kA
1 kV
1.25 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-4S-400
SPD AC 4W+G 277VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
4
1250
Type 2, Type 4
Base + Module
420VAC
20 kA
50 kA
100 kA
1.2 kV
1.8 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-2S-120
SPD AC 2W+G 120VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
2
1250
Type 2, Type 4
Base + Module
150VAC
20 kA
50 kA
100 kA
700 V
900 V
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-2S-230
SPD AC 2W+G 230VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
2
1250
Type 2, Type 4
Base + Module
275VAC
20 kA
50 kA
100 kA
1 kV
1.25 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-1S-400
SPD AC 1W+G 277VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
1
1250
Type 2, Type 4
Base + Module
420VAC
20 kA
50 kA
100 kA
1.2 kV
1.8 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-2S-400
SPD AC 2W+G 277VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
2
1250
Type 2, Type 4
Base + Module
420VAC
20 kA
50 kA
100 kA
1.2 kV
1.8 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-3S-400
SPD AC 3W+G 277VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
3
1250
Type 2, Type 4
Base + Module
420VAC
20 kA
50 kA
100 kA
1.2 kV
1.8 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-1S-120
SPD AC 1W+G 120VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
1
1250
Type 2, Type 4
Base + Module
150VAC
20 kA
50 kA
100 kA
700 V
900 V
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR
1250-1S-230
SPD AC 1W+G 230VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-50°C ~ 85°C
1
1250
Type 2, Type 4
Base + Module
275VAC
20 kA
50 kA
100 kA
1 kV
1.25 kV
Remote Signaling Contacts, Thermally Protected
CE, CSA, UR

About  Surge Protection Devices (SPDs)

Surge Protection Devices (SPDs) are both designed to protect electronic systems from voltage surges or transients, but they serve different purposes and operate in distinct ways. TVS diodes are semiconductor devices that are specifically designed to suppress transient voltage spikes by limiting or clamping the voltage at a specific level. They provide protection by diverting excess current away from sensitive components and can respond quickly to voltage spikes. TVS diodes are typically used at the circuit level to protect individual components or small groups of components within electronic devices. On the other hand, Surge Protection Devices (SPDs) are designed to protect entire electrical and electronic systems from temporary power surges or transients on AC or DC power lines. These surges can result from lightning strikes, switching operations, or other electrical disturbances. SPDs are installed at the point of entry of power lines into a building or within individual electrical circuits to safeguard connected equipment from potential damage caused by overvoltage. While TVS diodes are focused on protecting specific components from transient events, SPDs are geared towards safeguarding entire systems from power surges. SPDs utilize a combination of protective components such as metal oxide varistors (MOVs), gas discharge tubes (GDTs), or silicon avalanche diodes (SADs) to absorb and dissipate excessive energy generated during a surge event. In summary, TVS diodes and SPDs both play crucial roles in protecting electronic systems from voltage surges, but they operate at different levels of the system. TVS diodes are used to protect individual components within electronic circuits, while SPDs are employed to safeguard entire electrical and electronic systems from power surges on AC or DC power lines.