MRT100KP Series, TVS Diodes

Results:
90
Manufacturer
Series
Current - Peak Pulse (10/1000µs)
Voltage - Breakdown (Min)
Voltage - Clamping (Max) @ Ipp
Voltage - Reverse Standoff (Typ)
Bidirectional Channels
Unidirectional Channels
Operating Temperature
Applications
Capacitance @ Frequency
Grade
Mounting Type
Power - Peak Pulse
Supplier Device Package
Type
Qualification
Package / Case
Power Line Protection
Results remaining90
Applied Filters:
MRT100KP
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApplicationsCapacitance @ FrequencyBidirectional ChannelsOperating TemperatureGradePackage / CaseSupplier Device PackageSeriesTypeVoltage - Reverse Standoff (Typ)Voltage - Breakdown (Min)Voltage - Clamping (Max) @ IppCurrent - Peak Pulse (10/1000µs)Power - Peak PulsePower Line ProtectionUnidirectional ChannelsQualification
MRT100KP75CA
TVS DIODE BP 75VRWM 147.0VC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
75V
83.8V
147V
680A
100000W (100kW)
No
-
-
MRT100KP258CA
TVS DIODE BP 258VRWM 510.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
258V
288.2V
510V
198A
100000W (100kW)
No
-
-
MRT100KP102CA
TVS DIODE BP 102VRWM 198.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
102V
113.9V
198V
487A
100000W (100kW)
No
-
-
MRT100KP28A
TVS DIODE UP 28VRWM 58.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
28V
31.28V
58V
1715A (1.715kA)
100000W (100kW)
No
1
-
MRT100KP70A
TVS DIODE UP 70VRWM 138.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
70V
78.2V
138V
725A
100000W (100kW)
No
1
-
MRT100KP288CA
TVS DIODE BP 288VRWM 563.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
288V
321.7V
563V
177A
100000W (100kW)
No
-
-
MRT100KP51A
TVS DIODE UP 51VRWM 101.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
51V
57V
101V
990A
100000W (100kW)
No
1
-
MRT100KP45CA
TVS DIODE BP 45VRWM 88.5VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
45V
50.3V
88.5V
1130A (1.13kA)
100000W (100kW)
No
-
-
MRT100KP48A
TVS DIODE UP 48VRWM 94.3VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
48V
53.6V
94.3V
1061A (1.061kA)
100000W (100kW)
No
1
-
MRT100KP60CA
TVS DIODE BP 60VRWM 118.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
60V
67V
118V
848A
100000W (100kW)
No
-
-
MRT100KP300A
TVS DIODE UP 300VRWM 590.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
300V
333V
590V
170A
100000W (100kW)
No
1
-
MRT100KP43CA
TVS DIODE BP 43VRWM 84.5VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
43V
48V
84.5V
1184A (1.184kA)
100000W (100kW)
No
-
-
MRT100KP33CA
TVS DIODE BP 33VRWM 67.8VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
33V
36.9V
67.8V
1463A (1.463kA)
100000W (100kW)
No
-
-
MRT100KP108A
TVS DIODE UP 108VRWM 210.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
108V
120.6V
210V
460A
100000W (100kW)
No
1
-
MRT100KP180CA
TVS DIODE BP 180VRWM 354.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
1
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
180V
201.1V
354V
283A
100000W (100kW)
No
-
-
MRT100KP144A
TVS DIODE UP 144VRWM 267.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
144V
160.8V
267V
361A
100000W (100kW)
No
1
-
MRT100KP260A
TVS DIODE UP 260VRWM 512.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
260V
290.4V
512V
196A
100000W (100kW)
No
1
-
MRT100KP33A
TVS DIODE UP 33VRWM 67.8VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
33V
36.9V
67.8V
1463A (1.463kA)
100000W (100kW)
No
1
-
MRT100KP180A
TVS DIODE UP 180VRWM 354.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
180V
201.1V
354V
283A
100000W (100kW)
No
1
-
MRT100KP78A
TVS DIODE UP 78VRWM 153.0VC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
General Purpose
-
-
-55°C ~ 175°C (TJ)
-
P600, Axial
P600
MRT100KP
Zener
78V
87.1V
153V
655A
100000W (100kW)
No
1
-

About  TVS Diodes

TVS Diodes, also known as Transient Voltage Suppression Diodes, are semiconductor devices designed to protect electronic circuits from voltage surges or transients. They work by clamping the voltage to a safe level and diverting excessive current away from sensitive components. TVS diodes are typically made using diode technology, which allows them to conduct current in only one direction. They are designed to handle high-energy transients and can respond quickly to voltage spikes. When the voltage across the diode exceeds its breakdown voltage, it starts conducting and provides a low-resistance path for the transient current to flow through. This effectively limits the voltage seen by the protected circuitry, preventing damage. There are different types of TVS diodes available, including unidirectional and bidirectional variants. Unidirectional TVS diodes are designed to protect against voltage spikes in one direction, while bidirectional TVS diodes can handle voltage surges in both directions. TVS diodes have various characteristics that determine their performance and suitability for different applications. These characteristics include breakdown voltage, clamping voltage, peak pulse current, and power dissipation capability. The breakdown voltage refers to the voltage level at which the diode starts conducting and clamps the voltage. The clamping voltage is the voltage level maintained by the diode during a surge event. Peak pulse current represents the maximum current the diode can handle during a transient event, and power dissipation capability indicates the maximum power the diode can dissipate without being damaged. In summary, TVS diodes are important components used to protect electronic circuits from voltage surges or transients. By clamping the voltage and diverting excessive current, they safeguard sensitive components and ensure the reliability and longevity of electronic systems.