ATN Series, Time Delay Relays

Results:
9
Manufacturer
Series
Voltage - Supply
Circuit
Termination Style
Timing Initiate Method
Function
Delay Time
Timing Adjustment Method
Mounting Type
Contact Rating @ Voltage
Relay Type
Results remaining9
Applied Filters:
ATN
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeVoltage - SupplyContact Rating @ VoltageTermination StyleRelay TypeFunctionDelay TimeTiming Adjustment MethodTiming Initiate MethodSeriesCircuit
AT8N-1
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
12VDC
5A @ 250VAC
Plug In, 8 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C), DPDT (2 Form C)
AT11DN-2
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
24VAC/DC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
DPDT (2 Form C)
AT8N
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
100 ~ 240VAC, 24 ~ 240VDC
5A @ 250VAC
Plug In, 8 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C), DPDT (2 Form C)
AT8N-2
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
24VAC/DC
5A @ 250VAC
Plug In, 8 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C), DPDT (2 Form C)
AT11EN
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
100 ~ 240VAC, 24 ~ 240VDC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C)
AT11EN-1
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
12VDC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C)
AT11DN-1
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
12VDC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
DPDT (2 Form C)
AT11DN
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
100 ~ 240VAC, 24 ~ 240VDC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
DPDT (2 Form C)
AT11EN-2
Autonics
RELAY TIME DELAY 100HR 5A 250V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
24VAC/DC
5A @ 250VAC
Plug In, 11 Pin (Octal)
-
Programmable (Multi-Function)
0.05 Sec ~ 100 Hrs
Hand Dial
-
ATN
SPDT (1 Form C)

About  Time Delay Relays

Time Delay Relays (TDRs) are electromechanical devices utilized in various applications to enable the control of large loads using a smaller control signal. These relays incorporate a built-in time delay mechanism, allowing for precise timing in triggering the relay's operation. TDRs offer a wide range of functions to accommodate different timing requirements and operational scenarios. Some of the common functions provided by TDRs include: Interval Function: In this mode, the relay operates for a specified duration of time after receiving a control signal, and then deactivates until the next signal is received. It is often used for cyclic operations or periodic tasks. Off-Delay Function: With the off-delay function, the relay remains energized for a predetermined period after the control signal is removed. This delay ensures that the load remains powered for a specific duration before being turned off. On-Delay Function: The on-delay function introduces a time delay between the reception of the control signal and the activation of the relay. This delay allows for a temporary pause before the load is energized. One-Shot Function: In one-shot mode, the relay triggers a single output pulse of a defined duration when the control signal is received. This function is commonly used for momentary operations or as a pulse generator. Programmable (Multi-function) TDRs: These TDRs provide flexibility by offering multiple programmable timing functions in a single device. Users can configure the desired timing parameters according to their application requirements. Repeat Cycle Function: With the repeat cycle function, the relay alternates between on and off states at regular intervals, allowing for repetitive operation. Twin Timer Function: Twin timer TDRs feature two separate adjustable timers that operate independently, enabling more complex timing sequences or dual-output operations. Signal On-Off-Delay Function: This function combines both on-delay and off-delay functions, allowing for control of the load based on specific time periods for activation and deactivation. Star/Delta Controller: The star/delta controller function is commonly used in motor control applications. It provides a specific starting sequence for motors, optimizing their performance and reducing the initial high-current demand during startup. Time Delay Relays are versatile devices that find applications in various industries, including automation, control systems, HVAC, lighting, and motor control. They offer precise timing control and serve as reliable tools for coordinating the operation of large loads with smaller control signals.