KSD3 Series, Time Delay Relays

Results:
4
Manufacturer
Series
Delay Time
Voltage - Supply
Timing Adjustment Method
Timing Initiate Method
Function
Termination Style
Circuit
Mounting Type
Contact Rating @ Voltage
Relay Type
Results remaining4
Applied Filters:
KSD3
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeCircuitContact Rating @ VoltageTermination StyleVoltage - SupplySeriesRelay TypeFunctionDelay TimeTiming Adjustment MethodTiming Initiate Method
KSD3432A
RELAY TIME DELAY 1000SEC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
SPST-NO (1 Form A)
-
Quick Connect - 0.250" (6.3mm)
120VAC
KSD3
Solid State Relay
Repeat Cycle
10 Sec ~ 1000 Sec
Screwdriver Slot
Input Voltage
KSD3120A
RELAY TIME DELAY 10SEC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
SPST-NO (1 Form A)
-
Quick Connect - 0.250" (6.3mm)
12VDC
KSD3
Solid State Relay
Repeat Cycle
0.1 Sec ~ 10 Sec
External Resistor
Input Voltage
KSD3310.1SA
RELAY TIME DELAY 0.1SEC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
SPST-NO (1 Form A)
-
Quick Connect - 0.250" (6.3mm)
24VDC
KSD3
Solid State Relay
Repeat Cycle
Fixed, 0.1 Sec
Fixed
Input Voltage
KSD3415MA
RELAY TIME DELAY 5MIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
SPST-NO (1 Form A)
-
Quick Connect - 0.250" (6.3mm)
120VAC
KSD3
Solid State Relay
Repeat Cycle
Fixed, 5 Min
Fixed
Input Voltage

About  Time Delay Relays

Time Delay Relays (TDRs) are electromechanical devices utilized in various applications to enable the control of large loads using a smaller control signal. These relays incorporate a built-in time delay mechanism, allowing for precise timing in triggering the relay's operation. TDRs offer a wide range of functions to accommodate different timing requirements and operational scenarios. Some of the common functions provided by TDRs include: Interval Function: In this mode, the relay operates for a specified duration of time after receiving a control signal, and then deactivates until the next signal is received. It is often used for cyclic operations or periodic tasks. Off-Delay Function: With the off-delay function, the relay remains energized for a predetermined period after the control signal is removed. This delay ensures that the load remains powered for a specific duration before being turned off. On-Delay Function: The on-delay function introduces a time delay between the reception of the control signal and the activation of the relay. This delay allows for a temporary pause before the load is energized. One-Shot Function: In one-shot mode, the relay triggers a single output pulse of a defined duration when the control signal is received. This function is commonly used for momentary operations or as a pulse generator. Programmable (Multi-function) TDRs: These TDRs provide flexibility by offering multiple programmable timing functions in a single device. Users can configure the desired timing parameters according to their application requirements. Repeat Cycle Function: With the repeat cycle function, the relay alternates between on and off states at regular intervals, allowing for repetitive operation. Twin Timer Function: Twin timer TDRs feature two separate adjustable timers that operate independently, enabling more complex timing sequences or dual-output operations. Signal On-Off-Delay Function: This function combines both on-delay and off-delay functions, allowing for control of the load based on specific time periods for activation and deactivation. Star/Delta Controller: The star/delta controller function is commonly used in motor control applications. It provides a specific starting sequence for motors, optimizing their performance and reducing the initial high-current demand during startup. Time Delay Relays are versatile devices that find applications in various industries, including automation, control systems, HVAC, lighting, and motor control. They offer precise timing control and serve as reliable tools for coordinating the operation of large loads with smaller control signals.