ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureSeriesSize / DimensionQmax @ ThDelta Tmax @ ThHeightNumber of StagesCurrent - MaxVoltage - MaxResistanceFeatures
CP40439
PELTIER, 40 X 40 X 3.9, 4 A, WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
CP40, arcTEC
Square - 40.00mm L x 40.00mm W
45.0W @ 27°C
68°C @ 27°C
3.90mm
1
4 A
19.5 V
4.18 Ohms
Lead Wires, Sealed - Silicone RTV
CP4055485
PELTIER, 55 X 55 X 4.85, 4 A, WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
CP40, arcTEC
Square - 55.00mm L x 55.00mm W
63.0W @ 27°C
70°C @ 27°C
4.85mm
1
4 A
29.8 V
5.97 Ohms
Lead Wires, Sealed - Silicone RTV
CP40147
PELTIER, 15 X 15 X 4.7 MM, 4 A,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 15.00mm L x 15.00mm W
4.2W @ 27°C
68°C @ 27°C
4.70mm
1
4 A
2.1 V
420 mOhms
Lead Wires, Sealed - Silicone RTV
CP40247
PELTIER, 20 X 20 X 4.7 MM, 4 A,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 20.00mm L x 20.00mm W
7.5W @ 27°C
68°C @ 27°C
4.70mm
1
4 A
3.8 V
770 mOhms
Lead Wires, Sealed - Silicone RTV
CP40347
PELTIER, 30 X 30 X 4.7 MM, 4 A,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 30.00mm L x 30.00mm W
19.6W @ 27°C
68°C @ 27°C
4.70mm
1
4 A
8.6 V
1.76 Ohms
Lead Wires, Sealed - Silicone RTV
CP404046
PELTIER, 40 X 40 X 4.6, 4 A, WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
CP40, arcTEC
Square - 40.00mm L x 40.00mm W
55.7W @ 27°C
68°C @ 27°C
4.60mm
1
4 A
24.1 V
4.94 Ohms
Lead Wires, Sealed - Silicone RTV
CP40136
PELTIER MOD 15 X 3.6MM 4.0A INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 15.00mm L x 15.00mm W
8.1W @ 27°C
66°C @ 27°C
3.58mm
1
4 A
3.8 V
800 mOhms
Lead Wires, Sealed - Silicone RTV
CP40236
PELTIER MOD 20 X 3.6MM 4.0A INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 20.00mm L x 20.00mm W
18.7W @ 27°C
66°C @ 27°C
3.61mm
1
4 A
8.6 V
2 Ohms
Lead Wires, Sealed - Silicone RTV
CP40336
PELTIER MOD 30 X 3.6MM 4.0A INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 30.00mm L x 30.00mm W
33.4W @ 27°C
66°C @ 27°C
3.60mm
1
4 A
15.4 V
3.5 Ohms
Lead Wires, Sealed - Silicone RTV
CP40301547
PELTIER, 30 X 15 X 4.7 MM, 4 A,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Rectangular - 30.00mm L x 15.00mm W
8.4W @ 27°C
68°C @ 27°C
4.70mm
1
4 A
4.2 V
870 mOhms
Lead Wires, Sealed - Silicone RTV
CP40447
PELTIER, 40 X 40 X 4.7 MM, 4 A,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
80°C
CP40, arcTEC
Square - 40.00mm L x 40.00mm W
32.0W @ 27°C
68°C @ 27°C
4.70mm
1
4 A
15.4 V
3.15 Ohms
Lead Wires, Sealed - Silicone RTV

About  Thermoelectric, Peltier Modules

Thermoelectric modules, also known as Peltier modules, are specialized devices that utilize the Peltier effect to facilitate thermal transfer. These modules consist of two ceramic substrates with a junction in between. When an electric current is passed through the junction, heat is generated on one side while being absorbed on the other side. To effectively manage the heat generated, it is recommended to use a heatsink on the hot side of the module. The heatsink helps dissipate the excess heat and maintain optimal operating temperatures. The characteristics of thermoelectric modules include: Qmax @ Th: This refers to the maximum amount of heat that can be transferred by the module when the temperature at the hot side (Th) is maintained within specified limits. Delta Tmax @ Th: It represents the maximum temperature difference that can be achieved between the hot side and the cold side of the module when the temperature at the hot side (Th) is maintained within specified limits. Current max: This indicates the maximum current that the module can handle without experiencing any adverse effects or performance degradation. Voltage max: It denotes the maximum voltage that can be applied to the module without causing any damage or compromising its functionality. Resistance: This parameter relates to the electrical resistance exhibited by the module, which affects the efficiency and performance of the device. Operating temperature: It specifies the temperature range within which the module can function reliably and maintain its desired performance characteristics. By considering these characteristics, engineers and designers can select the appropriate thermoelectric modules for their specific thermal management requirements. These modules find applications in various industries, including electronics, telecommunications, automotive, aerospace, and medical, where precise temperature control and thermal regulation are crucial.