WL Series, Liquid Cooling, Heating

Results:
9
Manufacturer
Series
Fluid Capacity
Flow Rate
Dimensions - Overall
Power - Cooling
Connection Type
Current
Weight
Operating Temperature
Product Type
Voltage
Features
Ratings
Thermal Resistance @ GPM
Power Input
Results remaining9
Applied Filters:
WL
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesRatingsOperating TemperatureWeightConnection TypeSeriesProduct TypePower - CoolingCurrentVoltageFlow RatePower InputThermal Resistance @ GPMFluid CapacityDimensions - Overall
387009381
LA5000 5000W HEAT EXCHANGER L TO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
5°C ~ 40°C
-
-
WL
Active, Heat Exchanger
5000 W
3.3 A
200 ~ 240VAC
1.06GPM (4.0LPM)
-
-
6200ML (209.6 oz)
22.24" L x 18.43" W x 20.83" H (565.0mm x 468.0mm x 529.0mm)
1520.00
HEAT EXCHANGER 230V 4.4LPM 2000W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
10°C ~ 40°C
58 lbs (26.3 kg)
Walther Type MD 006
WL
Active, Heat Exchanger
2000 W
2.1 A
230VAC
1.16GPM (4.4LPM)
-
-
2500ML (84.5 oz)
11.81" L x 12.01" W x 18.88" H (300.0mm x 305.0mm x 505.0mm)
387002779
HEAT EXCHANGE LIQUID - AIR 3000W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
5°C ~ 40°C
85 lbs (38.6 kg)
9mm Press Fit
WL
-
3000 W
2.5 A
230VAC
-
-
-
3700ML (125.1 oz)
18.86" L x 15.67" W x 17.48" H (479.0mm x 398.0mm x 444.0mm)
1510.00
HEAT EXCHANGER 230V 4.4LPM 1000W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
10°C ~ 40°C
37 lbs (16.8 kg)
12mm Press Fit
WL
Active, Heat Exchanger
1000 W
2 A
230VAC
1.16GPM (4.4LPM)
-
-
1500ML (50.7 oz)
12.99" L x 11.50" W x 11.81" H (330.0mm x 292.0mm x 300.0mm)
1550.00
HEAT EXCHANGER 230V 6.5LPM 5000W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
5°C ~ 40°C
85 lbs (38.6 kg)
9mm Press Fit
WL
Active, Heat Exchanger
5000 W
2.6 A
230VAC
1.72GPM (6.5LPM)
-
-
5000ML (169.1 oz)
19.02" L x 15.98" W x 18.94" H (483.0mm x 406.0mm x 481.0mm)
1505.00
HEAT EXCHANGER 230V 2.3LPM 500W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
5°C ~ 40°C
24 lbs (10.9 kg)
8mm Press Fit
WL
Active, Heat Exchanger
500 W
1.2 A
230VAC
0.61GPM (2.3LPM)
-
-
1700ML (57.5 oz)
5.95" L x 12.09" W x 14.57" H (151.0mm x 307.0mm x 370.0mm)
1515.00
HEAT EXCHANGER 230V 4LPM 1500W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
5°C ~ 40°C
85 lbs (38.6 kg)
9mm Press Fit
WL
Active, Heat Exchanger
1500 W
2.5 A
230VAC
1.06GPM (4.0LPM)
-
-
3000ML (101.4 oz)
18.86" L x 15.67" W x 18.94" H (479.0mm x 398.0mm x 481.0mm)
1530.01
HEAT EXCHANGER 230V 6LPM 3000W
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Flow Rate, Bypass Valve Protection
-
5°C ~ 40°C
85 lbs (38.6 kg)
9mm Press Fit
WL
Active, Heat Exchanger
3000 W
2.5 A
230VAC
1.59GPM (6.0LPM)
-
-
3700ML (125.1 oz)
18.86" L x 15.67" W x 18.94" H (479.0mm x 398.0mm x 481.0mm)
387005598
LA5000, LIQUID TO AIR HEAT EXCHA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
5°C ~ 40°C
-
3/8" Quick Connect
WL
Active, Heat Exchanger
5000 W
3.3 A
200 ~ 240VAC
2.2GPM (8.3LPM)
-
-
6200ML (209.6 oz)
22.24" L x 18.43" W x 20.83" H (565.0mm x 468.0mm x 529.0mm)

About  Liquid Cooling, Heating

Thermal liquid cooling encompasses a diverse array of technologies, including heat exchangers, immersion chillers, recirculating chillers, recirculating chiller/heaters, and cold plates, catering to a wide range of power ratings from 22W to 5000W. These systems are designed to manage the transfer of heat within electronic and mechanical equipment by utilizing a liquid coolant. The flow rates of these thermal liquid cooling systems vary significantly, ranging from 0.61 gallons per minute (2.3 liters per minute) to 3.96 gallons per minute (15.0 liters per minute). This wide range allows for flexibility in accommodating different cooling requirements across various applications. Moreover, the thermal resistance of these systems also spans a broad spectrum, from 0.0055°C/W at 2.0 gallons per minute to 0.084°C/W at 1.5 gallons per minute. This variation in thermal resistance provides the capability to tailor the cooling performance based on specific heat dissipation needs and environmental conditions. These thermal liquid cooling solutions are utilized across industries where precise temperature control and efficient heat dissipation are critical. They find applications in cooling high-power electronic components, laser systems, medical equipment, and industrial machinery, among others. In summary, thermal liquid cooling systems encompass a diverse range of technologies designed to manage heat transfer within electronic and mechanical equipment. With varying flow rates and thermal resistance, these solutions offer flexibility and precision in addressing the cooling needs of different applications, contributing to the reliability and optimal performance of critical systems.