MHP-TAC Series, Thermal Cutoffs (Thermal Fuses)

Results:
18
Manufacturer
Series
Rated Functioning Temperature
Maximum Temperature Limit
Type
Voltage Rating - DC
Reset Temperature
Package / Case
Voltage Rating - AC
Current Rating (Amps)
Approval Agency
Holding Temperature
Results remaining18
Applied Filters:
MHP-TAC
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - ACPackage / CaseApproval AgencyCurrent Rating (Amps)SeriesTypeHolding TemperatureRated Functioning TemperatureReset TemperatureVoltage Rating - DCMaximum Temperature Limit
MHP-TAC15-12-90
THERMOSTAT 90DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
90°C (194°F)
40°C (104°F)
12
-
MHP-TAC15-12-90N
THERMOSTAT 90DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
90°C (194°F)
40°C (104°F)
12
-
MHP-TAC15-12-82N
THERMOSTAT 82DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
82°C (180°F)
40°C (104°F)
12
-
MHP-TAC15-12-77N
THERMOSTAT 77DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
77°C (171°F)
40°C (104°F)
12
-
MHP-TAC15-12-72
THERMOSTAT 72DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
72°C (162°F)
40°C (104°F)
12
-
MHP-TAC15-12-77
THERMOSTAT 77DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
77°C (171°F)
40°C (104°F)
12
-
MHP-TAC6-12-82
THERMOSTAT 82DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
82°C (180°F)
40°C (104°F)
12
-
MHP-TAC6-12-72
THERMOSTAT 72DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
72°C (162°F)
40°C (104°F)
12
-
MHP-TAC15-12-85N
THERMOSTAT 85DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
85°C (185°F)
40°C (104°F)
12
-
MHP-TAC6-12-77N
THERMOSTAT 77DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
77°C (171°F)
40°C (104°F)
12
-
MHP-TAC15-12-82
THERMOSTAT 82DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
82°C (180°F)
40°C (104°F)
12
-
MHP-TAC6-12-85
THERMOSTAT 85DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
85°C (185°F)
40°C (104°F)
12
-
MHP-TAC6-12-77
THERMOSTAT 77DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
77°C (171°F)
40°C (104°F)
12
-
MHP-TAC15-12-72N
THERMOSTAT 72DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
72°C (162°F)
40°C (104°F)
12
-
MHP-TAC15-12-85
THERMOSTAT 85DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
85°C (185°F)
40°C (104°F)
12
-
MHP-TAC6-12-85N
THERMOSTAT 85DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
85°C (185°F)
40°C (104°F)
12
-
MHP-TAC6-12-82N
THERMOSTAT 82DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
82°C (180°F)
40°C (104°F)
12
-
MHP-TAC6-12-72N
THERMOSTAT 72DEG C SPST-NC STRAP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Nonstandard
-
25 A
MHP-TAC
Breaker
-
72°C (162°F)
40°C (104°F)
12
-

About  Thermal Cutoffs (Thermal Fuses)

Thermal cutoffs, also known as thermal fuses, are engineered to protect components from excessive temperatures. In the event that the preset operating temperature is surpassed, the thermal cutoff will activate by opening up in the electrical circuit, thereby interrupting the current flow to prevent damage.