3106 Series, Thermostats - Mechanical

Results:
46
Manufacturer
Series
Switching Cycles
Reset Temperature
Current Rating - DC
Package / Case
Termination Style
Tolerance
Circuit
Current Rating - AC
Mounting Type
Switching Temperature
Results remaining46
Applied Filters:
3106
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StylePackage / CaseToleranceCircuitSwitching TemperatureSeriesReset TemperatureCurrent Rating - ACCurrent Rating - DCSwitching Cycles
310600010053
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600430045
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00430038
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00040037
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600030172
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600030156
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00030148
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00030136
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600030057
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600010055
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600450077
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00010052
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   02220003
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310601950001
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310601910004
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310601450015
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00830012
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
3106   00450142
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600450140
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K
310600450136
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
3106
-
0.1A (120V)
0.5A (50V), 0.5A (24V)
100K

Thermostats - Mechanical

Mechanical Thermostats are specialized devices that play a crucial role in maintaining the safety of components exposed to extreme temperatures. These thermostats are designed to control circuits by either opening or closing them when the temperature surpasses a certain threshold, known as the switching temperature. The switching temperature can be adjusted within a range of 14°F to 500°F to suit specific application requirements. To ensure optimal functionality and flexibility, Mechanical Thermostats offer different reset temperature options. These include Manual Reset, One Shot, and a temperature range of 20°F to 440°F. The choice of reset temperature depends on the desired application and the level of temperature control needed. Furthermore, Mechanical Thermostats are assigned current ratings, which indicate the maximum current that they can handle. These ratings typically range from 0.045 A to 25 A, allowing for customization based on the electrical load and safety considerations of the components being protected. The primary purpose of Mechanical Thermostats is to provide reliable protection and prevent damage to components in various settings. They are commonly used in industrial applications where temperature regulation is critical, such as in manufacturing processes, HVAC systems, and electrical equipment. Mechanical Thermostats are built with durability and robustness in mind, ensuring their reliability even in challenging environments. They are designed to withstand harsh conditions and deliver accurate temperature control, making them indispensable devices for safeguarding components and preventing potential hazards. In summary, Mechanical Thermostats are specifically engineered to protect components from excessive temperatures. By opening or closing circuits when the switching temperature is exceeded, these thermostats ensure the safety and integrity of the system. With adjustable switching temperatures, different reset temperature options, and a range of current ratings, Mechanical Thermostats offer versatility and customization. Whether used in industrial processes or electrical systems, these thermostats provide reliable temperature control and component protection.