Signal Conditioners and Isolators

Results:
911
Manufacturer
Series
Input Range (Current, Voltage)
Input Range (Additional)
Voltage - Supply
Output Range
Isolation
Operating Temperature
Features
Input Type
Type
Output Type
Termination Style
Mounting Type
Results remaining911
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeVoltage - SupplyOutput TypeTermination StyleSeriesTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output RangeIsolation
3RS70032DE00
4-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Current
Spring Terminal
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
4 ~ 20mA
50V
IAMS0022
MOD IAMS ANALOG/DUAL SETPOINT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Alarm Relay (2)
-20°C ~ 60°C
DIN Rail
21.6 ~ 253VAC, 19.2 ~ 300VDC
Current, Voltage
Screw Terminal
IAMS
Signal Conditioner
Current, Voltage, Resistance, Temperature
0 ~ 20mA, 0 ~ 10V (Configurable)
0.01 ~ 100kOhm, -200°C ~ 2300°C
0 ~ 20mA, 0 ~ 12V (Configurable)
2300V
2813541
3-WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 65°C
DIN Rail
24VDC
Voltage
Screw Terminal
MINI MCR
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
1500V (Test)
8391.0
SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 55°C
DIN Rail
-
Current
Screw Terminal
-
Signal Conditioner
-
-
-
30mA
-
IAMA0001
MOD UNIV SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
Loop Powered
Current, Voltage
Screw Terminal
IAMA
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
0 ~ 20mA, 0 ~ 10V (Configurable)
300V (Working), 2500V (Test)
857-820
JUMPFLEX TRANSDUCER; KTY TRANSDU
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Current, Voltage
Spring Terminal
857
Signal Conditioner
Temperature
-
-
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
2901997
TWO-CHANNEL INPUT LOOP-POWERED 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
Loop Powered
Current
Spring Terminal
MINI MCR
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
3000V (Test)
3RS70001AE00
0-10V TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Voltage
Screw Terminal
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
0 ~ 10V
50V
3RS70022DE00
0-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Current
Spring Terminal
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
4 ~ 20mA
50V
3RS70022AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Voltage
Spring Terminal
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
0 ~ 10V
50V
RLN42-8M2B+LA
Endress+Hauser
ISOLATION AMPLIFIER, 2-CHANNEL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 60°C
DIN Rail
19.2 ~ 253VAC/VDC
-
-
RLN42
Isolation Amplifier
-
-
-
-
375V
3RS70022CE00
0-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Current
Spring Terminal
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
0 ~ 20mA
50V
3RS70002DE00
0-10V TO 4-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Current
Spring Terminal
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
4 ~ 20mA
50V
3RS70031DE00
4-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Current
Screw Terminal
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
4 ~ 20mA
50V
3RS70201ET00
4-20MA TO 4-20MA CNVRTR, PASSIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
-
Current
Screw Terminal
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
4 ~ 20mA
50V
857-415
ISOLATION AMPLIFIER; CURRENT INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Voltage
Spring Terminal
857
Isolation Amplifier
Current
0 ~ 20mA
0 ~ 50Ohm
0 ~ 10V
2500V (Test)
857-812
JUMPFLEX TRANSDUCER; TEMPERATURE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Current, Voltage
Spring Terminal
857
Signal Conditioner
Temperature
-
0°C ~ 1600°C
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
6756.2
SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 55°C
DIN Rail
24V
Voltage
Screw Terminal
-
-
-
-
-
12V
-
857-979
SUPPLY AND THROUGH MODULE; 2,50
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
33VAC/DC
-
Spring Terminal
-
-
-
-
-
-
-
2904931
2-CHANNEL EX I OUTPUT SIGNAL CON
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
Current
Screw Terminal
MACX MCR
Signal Conditioner
Current
0 ~ 24mA
-
0 ~ 24mA
375V

Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.