MACX MCR Series, Signal Conditioners and Isolators

Results:
34
Manufacturer
Series
Output Range
Voltage - Supply
Isolation
Input Range (Current, Voltage)
Operating Temperature
Type
Input Type
Termination Style
Output Type
Mounting Type
Input Range (Additional)
Features
Results remaining34
Applied Filters:
MACX MCR
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeSeriesTermination StyleOutput TypeIsolationOutput RangeTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Voltage - Supply
2907706
TWO-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2865421
SET CONSISTING OF A 1 A MEASURIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 24mA
Signal Conditioner
Current
0 ~ 24mA
-
24VDC
2865405
ISOLATED AMP 2 CHAN DIN RAIL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2907705
SINGLE-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Spring Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2924016
REPEATER PWR SUPP 4-20MA DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Spring Terminal
Current
375V
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2924029
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Spring Terminal
Current, Voltage
375V
0 ~ 20mA, 0 ~ 5V (Configurable)
Isolation Amplifier
Current
0 ~ 20mA (Configurable)
-
24 ~ 230VAC/DC
2905281
TWO-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Spring Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2904089
MACX MCR-SL-RPSS-2I-2I
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
4 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2904090
MACX MCR-SL-RPSS-2I-2I-SP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
4 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2924825
MACX MCR-SL-RPSSI-2I
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 70°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2905279
SINGLE-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Spring Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2905278
SINGLE-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2865340
ISOLATED AMP 2 CHAN DIN RAIL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2908064
OUTPUT SIGNAL CONDITIONER, HART.
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 24mA
Signal Conditioner
Current
0 ~ 24mA
-
24VDC
2924032
EX-I OUTPUT ISOLATING AMPLIFIER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2905280
TWO-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2811284
SIGNAL CONDITIONER ISO AMP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 70°C
DIN Rail
MACX MCR
Spring Terminal
Current, Voltage
-
0 ~ 20mA, 0 ~ 10V (Configurable)
Signal Conditioner
Current, Voltage
±100mA, ±100V (Configurable)
-
12 ~ 24VDC
2865382
TRANSDUCER MEASURING 0/4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
4 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
24VDC
2907704
SINGLE-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
MACX MCR
Screw Terminal
Current
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
Loop Powered
2908062
EX I OUTPUT SIGNAL CONDITIONER,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
MACX MCR
Screw Terminal
Current
375V
0 ~ 24mA
Signal Conditioner
Current
0 ~ 24mA
-
24VDC

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.