MCR Series, Signal Conditioners and Isolators

Results:
19
Manufacturer
Series
Input Range (Current, Voltage)
Output Range
Operating Temperature
Voltage - Supply
Type
Isolation
Input Type
Output Type
Termination Style
Mounting Type
Input Range (Additional)
Features
Results remaining19
Applied Filters:
MCR
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOutput TypeOperating TemperatureMounting TypeSeriesVoltage - SupplyTermination StyleOutput RangeTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Isolation
2814498
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
±10V
Signal Conditioner
Current
±20mA
-
1500V (Test)
2814854
SIGNAL DUPLICATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 55°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
Signal Conditioner Multiplier
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
1500V (Test)
2814841
LOOP POWERED ISOLATOR 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-10°C ~ 70°C
DIN Rail
MCR
Loop Powered
-
0 ~ 20mA
Passive Isolator
Current
0 ~ 20mA
-
4000V (Test)
2814838
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-10°C ~ 70°C
DIN Rail
MCR
20 ~ 253VAC/DC
Screw Terminal
0 ~ 20mA, 0 ~ 10V
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V
-
4000V (Test)
2814867
SIGNAL MULTIPLIER 4-WAY SPLITTER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 55°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
35mA, 0 ~ 10VDC (Configurable)
Signal Conditioner Multiplier
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
1500V (Test)
2810887
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-20°C ~ 65°C
DIN Rail
MCR
18 ~ 30VDC
Screw Terminal
0 ~ 10V (Configurable)
Signal Conditioner
Voltage
0 ~ 10V (Configurable)
-
1500V (Test)
2814469
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
±10V
Isolation Amplifier
Voltage
±10V
-
1500V (Test)
2814537
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
4 ~ 20mA
Signal Conditioner
Voltage
0 ~ 10V
-
1500V (Test)
2814553
REPEATER POWER SUPPLY 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-20°C ~ 65°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
4 ~ 20mA
Isolation Amplifier
Current
4 ~ 20mA
-
1000V (Test)
2814252
LOOP POWERED ISOLATOR 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 65°C
DIN Rail
MCR
Loop Powered
-
4 ~ 20mA
Passive Isolator
Current
4 ~ 20mA
-
1500V (Test)
2814511
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
0 ~ 10V
Signal Conditioner
Current
4 ~ 20mA
-
1500V (Test)
2814524
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
0 ~ 20mA
Isolation Amplifier
Current
4 ~ 20mA
-
1500V (Test)
2814540
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
4 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
1500V (Test)
2814508
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
MCR
20 ~ 30VDC
Screw Terminal
0 ~ 20mA
Isolation Amplifier
Current
0 ~ 20mA
-
1500V (Test)
2814045
MCR PASSIVE ISOLATOR 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-10°C ~ 70°C
DIN Rail
MCR
Loop Powered
Screw Terminal
0 ~ 20mA
Passive Isolator
Current, Voltage
0 ~ 20mA, 30V
-
-
2814029
MCR PASSIVE ISOLATOR 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-10°C ~ 70°C
DIN Rail
MCR
Loop Powered
Screw Terminal
0 ~ 20mA
Passive Isolator
Current, Voltage
0 ~ 20mA, 30V
-
-
2814016
MCR PASSIVE ISOLATOR 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-10°C ~ 70°C
DIN Rail
MCR
Loop Powered
-
0 ~ 20mA
Passive Isolator
Current, Voltage
0 ~ 20mA, 30V
-
-
2810939
MCR 3-WAY ISOLATING AMPLIFIER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-20°C ~ 65°C
DIN Rail
MCR
-
Screw Terminal
0 ~ 10V (Configurable)
Signal Conditioner
Voltage
0 ~ 10V (Configurable)
-
1500V (Test)
2814058-USA
MCR PASSIVE ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 65°C
DIN Rail
MCR
Loop Powered
Screw Terminal
4 ~ 20mA
Passive Isolator
Current, Voltage
4 ~ 20mA, 30V
-
1500V (Test)

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.