APD Series, Signal Conditioners and Isolators

Results:
22
Manufacturer
Series
Input Range (Current, Voltage)
Input Type
Features
Output Range
Output Type
Input Range (Additional)
Type
Voltage - Supply
Isolation
Operating Temperature
Termination Style
Mounting Type
Results remaining22
Applied Filters:
APD
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeOperating TemperatureTermination StyleTypeInput TypeInput Range (Additional)Output TypeSeriesOutput RangeIsolationFeaturesVoltage - SupplyInput Range (Current, Voltage)
APD 6380
AC to DC Transmitter, Field Conf
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
True RMS
85 ~ 265VAC, 60 ~ 300VDC
0 ~ 300VAC, 0 ~ 200mA (Configurable)
APD 4058
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Non-Isolated Amplifier
Loadcell
0.1 ~ 10kOhm
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
-
Excitation Supply
85 ~ 265VAC, 60 ~ 300VDC
0.5 ~ 120mV, 1 ~ 10VDC (Configurable)
APD 4300 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current
-
Current
APD
4 ~ 20mA
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
4 ~ 20mA
APD 4008 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Resistance
100 ~ 1MOhm
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
-
APD 4380 D
DC to DC Isolating Transmitter
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 50mA, 0 ~ 130V, ±5 ~ 65V (Configurable)
APD 8000
Universal Input to DC Transmitte
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage, Resistance, Temperature
-
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
85 ~ 265VAC, 60 ~ 300VDC
0 ~ 20mA, ±10V (Configurable)
APD 4930
4-20mA DC Isolating Splitter
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
4 ~ 20mA
1200V
Input Loop Supply, Output LoopTracker LED
85 ~ 265VAC, 60 ~ 300VDC
4 ~ 20mA
APD 4930 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
4 ~ 20mA
1200V
Input Loop Supply, Output LoopTracker LED
10 ~ 32VAC, 9 ~ 30VDC
4 ~ 20mA
APD 4008
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Resistance
100 ~ 1MOhm
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
LoopTracker LEDs, Output Test Button
85 ~ 265VAC, 60 ~ 300VDC
-
APD 4300
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current
-
Current
APD
4 ~ 20mA
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
85 ~ 265VAC, 60 ~ 300VDC
4 ~ 20mA
APD 4059 D
Strain Gage to DC Isolating Xmtr
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Loadcell
0.1 ~ 10kOhm
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
Excitation Supply
10 ~ 32VAC, 9 ~ 30VDC
0.5 ~ 40mV, 1 ~ 10VDC (Configurable)
APD 4059
Strain Gage to DC Isolating Xmtr
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Loadcell
0.1 ~ 10kOhm
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
Excitation Supply
85 ~ 265VAC, 60 ~ 300VDC
0.5 ~ 40mV, 1 ~ 10VDC (Configurable)
APD HV-DC
High Voltage DC to DC Isolator
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Voltage
-
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
LoopTracker LEDs, Output Test Button
85 ~ 265VAC, 60 ~ 300VDC
0 ~ 1200V (Configurable)
APD 6380 D
AC to DC Transmitter, Field Conf
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
True RMS
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 300VAC, 0 ~ 200mA (Configurable)
APD 7500 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Frequency
APD
0 ~ 1500 Hz, 0 ~ 30 kHz (Configurable)
1200V
LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 20mA, ±10V (Configurable)
APD 8000 D
Universal Input to DC Transmitte
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage, Resistance, Temperature
-
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 20mA, ±10V (Configurable)
APD HV-DC D
High Voltage DC to DC Isolator
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Voltage
-
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 1200V (Configurable)
APD 4380
DC to DC Isolating Transmitter
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Current, Voltage
-
Current, Voltage
APD
0 ~ 20mA, ±10V (Configurable)
1200V
Input Loop Supply, LoopTracker LEDs, Output Test Button
85 ~ 265VAC, 60 ~ 300VDC
0 ~ 50mA, 0 ~ 130V, ±5 ~ 65V (Configurable)
APD 7580 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Signal Conditioner
Frequency
-
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
1200V
LoopTracker LEDs, Output Test Button
10 ~ 32VAC, 9 ~ 30VDC
0 ~ 100Hz, 0 ~ 30kHz (Configurable)
APD 4058 D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
-10°C ~ 60°C
Screw Terminal
Non-Isolated Amplifier
Loadcell
0.1 ~ 10kOhm
Current, Voltage
APD
0 ~ 20mA, 0 ~ 10V, ±10V (Configurable)
-
Excitation Supply
10 ~ 32VAC, 9 ~ 30VDC
0.5 ~ 120mV, 1 ~ 10VDC (Configurable)

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.