3RS7 Series, Signal Conditioners and Isolators

Results:
36
Manufacturer
Series
Output Range
Input Range (Current, Voltage)
Output Type
Input Type
Voltage - Supply
Input Range (Additional)
Termination Style
Type
Isolation
Operating Temperature
Mounting Type
Features
Results remaining36
Applied Filters:
3RS7
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOutput TypeOperating TemperatureMounting TypeVoltage - SupplyTermination StyleOutput RangeSeriesTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Isolation
3RS70052KE00
SWITCHABLE MULTI-RANGE CNVRTR, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
-
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
50V
3RS70051KW00
SWTCHBL MULTI-RANGE CNVRTR, 24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 60°C
DIN Rail
24 ~ 240VAC/DC
Screw Terminal
-
3RS7
Signal Conditioner
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
300V
3RS70061FW00
SWTCHBL UNIVERSAL CNVRTR, 24-240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24 ~ 240VAC/DC
Screw Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
3RS7
Isolation Amplifier
Current, Resistance, Voltage
±20mA, 0 ~ 20V (Configurable)
100 Ohm, 330k Ohm
300V
3RS70252FW00
SWTCHBL MULTI-RANGE CNVRTR, 24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24 ~ 240VAC/DC
Spring Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
300V
3RS70201ET00
4-20MA TO 4-20MA CNVRTR, PASSIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
-
Screw Terminal
4 ~ 20mA
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
50V
3RS70021AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
0 ~ 10V
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
50V
3RS70032CE00
4-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 20mA
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
50V
3RS70031CE00
4-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
0 ~ 20mA
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
50V
3RS70001CE00
0-10V TO 0-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
0 ~ 20mA
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
50V
3RS70002AE00
0-10V TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 10V
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
50V
3RS70002DE00
0-10V TO 4-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
4 ~ 20mA
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
50V
3RS70022CE00
0-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 20mA
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
50V
3RS70022AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 10V
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
50V
3RS70002CE00
0-10V TO 0-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 20mA
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
50V
3RS70052FW00
SWTCHBL MULTI-RANGE CNVRTR, 24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24 ~ 240VAC/DC
Spring Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
3RS7
Signal Conditioner
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
300V
3RS70001AE00
0-10V TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
0 ~ 10V
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
50V
3RS70062FE00
SWTCHBL UNIVERSAL CNVRTR, 24VAC/
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
3RS7
Isolation Amplifier
Current, Resistance, Voltage
±20mA, 0 ~ 20V (Configurable)
100 Ohm, 330k Ohm
50V
3RS70061FE00
SWTCHBL UNIVERSAL CNVRTR, 24VAC/
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
0 ~ 20mA, 0 ~ 20V (Configurable)
3RS7
Isolation Amplifier
Current, Resistance, Voltage
±20mA, 0 ~ 20V (Configurable)
100 Ohm, 330k Ohm
50V
3RS70051KE00
SWITCHABLE MULTI-RANGE CNVRTR, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
-
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
50V
3RS70252FE00
SWTCHBL MULTI-RANGE CNVRTR, 24VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Current, Voltage
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
0 ~ 20mA, 0 ~ 10V (Configurable)
3RS7
Signal Conditioner
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
50V

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.