CGD Series, Protection Relays & Systems

Results:
20
Manufacturer
Series
Trip Range
Voltage - Supply
Function
Operating Temperature
Termination Style
Delay Time
Features
Mounting Type
Results remaining20
Applied Filters:
CGD
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureVoltage - SupplyTermination StyleMounting TypeSeriesFunctionTrip RangeDelay TimeFeatures
CGD60-SE110V
DSSOLR(7SEG) SCREW EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60T220V
DSSOLR(7SEG) TUNNEL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60-T110V
DSSOLR(7SEG) TUNNEL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD06T220V
DSSOLR(7SEG) TUNNEL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06-T110V
DSSOLR(7SEG) TUNNEL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD60SZ220V-65MM
DSSOLR(7SEG) SCREW GND FLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60-SZ110V-65MM
DSSOLR(7SEG) SCREW GND FLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD06SZ220V-50MM
DSSOLR(7SEG) SCREW GND FLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06-SZ110V-50MM
DSSOLR(7SEG) SCREW GND FLT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD60SE220V
DSSOLR(7SEG) SCREW EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD06-S110V
DSSOLR(7SEG) SCREW
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06SE220V
DSSOLR(7SEG) SCREW EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06-SE110V
DSSOLR(7SEG) SCREW EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD60TE220V
DSSOLR(7SEG) TUNNEL EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60-TE110V
DSSOLR(7SEG) TUNNEL EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60S220V
DSSOLR(7SEG) SCREW
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD60-S110V
DSSOLR(7SEG) SCREW
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
5 ~ 60A
0 ~ 60s
Manual Reset, Test Button
CGD06TE220V
DSSOLR(7SEG) TUNNEL EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06-TE110V
DSSOLR(7SEG) TUNNEL EXT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
110VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button
CGD06-S220V
DSSOLR(7SEG) SCREW
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-25°C ~ 70°C
220VAC
Screw Terminal
Chassis Mount, DIN Rail
CGD
Multiple
500mA ~ 6A
0 ~ 60s
Manual Reset, Test Button

Protection Relays & Systems

Protection relays are essential components of industrial systems designed to detect and respond to abnormal operating conditions, preventing damage to equipment and ensuring the safety of personnel. These relays constantly monitor the system for any deviations from normal operating parameters, triggering an alert or disconnecting the offending device from the network to prevent potential hazards. Arc-Flash Detection: Arc-flash detection relays are used to monitor electrical activity and detect dangerous arcing faults in electrical systems. These relays can quickly identify arc-flash events and trigger a system shutdown to prevent further damage. Temperature Monitoring: Temperature monitoring relays are employed to detect overheating conditions in electrical equipment, such as motors and transformers. These relays can sense temperature changes in real-time and initiate corrective measures before the equipment is damaged. Ground Fault Detection: Ground fault detection relays are utilized to detect faults in the grounding system of electrical equipment, preventing electrical shocks and minimizing damage to the equipment. Over-Current Protection: Over-current protection relays are designed to detect excessive current flow in electrical systems, such as short circuits or overloads. These devices can quickly disconnect the affected circuit, limiting the damage and preventing disruption to the rest of the system. Over-Voltage Protection: Over-voltage protection relays are used to detect and protect against voltage surges or spikes in electrical systems, preventing damage to sensitive equipment and reducing the risk of electrical fires. Reverse Power Flow Protection: Reverse power flow protection relays are utilized in power generation systems to detect and prevent the reverse flow of power into the generator, protecting against potential damage and improving system stability. Over-Frequency and Under-Frequency Protection: Over-frequency and under-frequency protection relays are employed to detect deviations from normal frequency levels in electrical systems, such as those caused by load shedding or generator failure. These relays can initiate corrective measures to restore the system to its normal operating frequency. Phase Loss, Sequence, or Imbalance Protection: Phase loss, sequence, or imbalance protection relays are used to detect and prevent electrical system faults caused by phase loss, sequence deviation, or voltage imbalances, protecting against equipment damage and reducing the risk of electrical hazards. In summary, protection relays serve as critical components of industrial systems designed to detect and respond to abnormal operating conditions, preventing damage to equipment and ensuring the safety of personnel. These relays employ a variety of detection functions, including arc-flash, temperature monitoring, ground fault, over-current, over-voltage, reverse power flow, over-frequency, under-frequency, and phase loss, sequence, or imbalance protection. By constantly monitoring the system for deviations from normal operating parameters, these relays facilitate the efficient and reliable operation of industrial systems, ultimately supporting the performance and functionality of a wide array of industrial machinery and equipment.