MIP Series, Pressure Sensors, Transducers

Results:
7
Manufacturer
Series
Operating Pressure
Port Size
Pressure Type
Maximum Pressure
Operating Temperature
Applications
Termination Style
Output Type
Port Style
Grade
Mounting Type
Supplier Device Package
Accuracy
Qualification
Package / Case
Voltage - Supply
Output
Features
Results remaining7
Applied Filters:
MIP
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSupplier Device PackageTermination StyleApplicationsVoltage - SupplyOperating TemperaturePackage / CaseOutput TypeAccuracyOutputFeaturesGradePressure TypeOperating PressurePort SizePort StyleSeriesQualificationMaximum Pressure
MIPAN2XX100PSAAX
1+
¥120.4225
5+
¥113.7324
10+
¥107.0423
Quantity
826 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
100PSI (689.48kPa)
Male - 1/8" (3.18mm) NPT
Threaded
MIP
-
348.09PSI (2400kPa)
MIPAF1XX667PSAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
667PSI (4598.8kPa)
Female - 7/16" (11.11mm) UNF Schrader
Threaded
MIP
-
1740.45PSI (12000kPa)
MIPAN1XX100PSAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
100PSI (689.48kPa)
Male - 1/4" (6.35mm) NPT
Threaded
MIP
-
348.09PSI (2400kPa)
MIPAG1XX050BSAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
725.19PSI (5000kPa)
Male - 1/4" (6.35mm) BSPP
Threaded
MIP
-
1740.45PSI (12000kPa)
MIPAF1XX250PSAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
250PSI (1723.69kPa)
Female - 7/16" (11.11mm) UNF Schrader
Threaded
MIP
-
1740.45PSI (12000kPa)
MIPAM1XX050PAAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Absolute
50PSI (344.74kPa)
Male - M12 x 1.5
Threaded
MIP
-
348.09PSI (2400kPa)
MIPAN2XX500PSAAX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Connector
-
4.75V ~ 5.25V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.15%
0.5 V ~ 4.5 V
Temperature Compensated
-
Sealed Gauge
500PSI (3447.38kPa)
Male - 1/8" (3.18mm) NPT
Threaded
MIP
-
1740.45PSI (12000kPa)

About  Pressure Sensors, Transducers

Pressure sensors or transducers play a crucial role in detecting and accurately responding to the presence or variations in applied force. These devices are specifically designed to measure different types of pressure, including Absolute, Compound, Differential, Gauge, Sealed Gauge, Switch, Vacuum, and Vented Gauge. They are capable of operating within a wide range of pressures, spanning from -100PSI (-689.48kPa) to 20000PSI (137895.15kPa). Absolute pressure sensors are engineered to measure pressure relative to a perfect vacuum, providing an accurate indication of the absolute pressure at a given point. Compound pressure sensors, on the other hand, are designed to measure both positive and negative pressures, making them suitable for applications where pressure variations can occur in either direction. Differential pressure sensors are utilized to determine the difference in pressure between two points, enabling the measurement of pressure variances across various systems and components. Gauge pressure sensors, on the other hand, measure pressure relative to atmospheric pressure, providing an indication of the pressure above or below atmospheric levels. Sealed gauge pressure sensors are specifically designed to reference pressure against a fixed reference point, ensuring accurate measurements relative to a specific atmospheric pressure or another predetermined reference pressure. Switch pressure sensors are equipped with a threshold mechanism that triggers a response when the pressure exceeds or falls below a predefined set value, making them ideal for applications requiring pressure-based control or alarm systems. Vacuum pressure sensors are engineered to measure pressures below atmospheric levels, while vented gauge pressure sensors provide accurate measurements relative to a reference pressure, typically vented to atmospheric conditions. These pressure sensors or transducers are essential components used in a wide range of industries and applications, including manufacturing, automotive, aerospace, and process control. They contribute to the precise monitoring, control, and safety of systems by delivering accurate pressure measurements, facilitating efficient operation and preventing potential issues caused by excessive or insufficient pressure. In summary, pressure sensors or transducers are designed to detect and respond to force variations. They encompass various pressure types and operate within a broad pressure range, catering to diverse industrial applications. These sensors play a pivotal role in ensuring accurate pressure measurements, enabling efficient system operation and enhancing safety in numerous industries.