19 mm Series, Pressure Sensors, Transducers

Results:
165
Manufacturer
Series
Operating Pressure
Maximum Pressure
Maximum Pressure (PSI)
Port Size
Output
Port Style
Pressure Type
Voltage - Supply
Applications
Package / Case
Features
Operating Temperature
Termination Style
Output Type
Grade
Mounting Type
Supplier Device Package
Accuracy
Qualification
Results remaining165
Applied Filters:
19 mm
Select
ImageProduct DetailPriceAvailabilityECAD ModelSupplier Device PackageApplicationsVoltage - SupplyOperating TemperaturePackage / CaseOutput TypeAccuracyTermination StyleFeaturesPressure TypeOperating PressureOutputPort SizePort StyleMaximum Pressure (PSI)Series
19C300PG4L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
300PSI (2068.43kPa)
0 mV ~ 100 mV
Male - 1/8" (3.18mm) NPT
Threaded
900PSI (6205.28kPa)
19 mm
19C100PG8L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
100PSI (689.48kPa)
0 mV ~ 100 mV
-
No Port
300PSI (2068.43kPa)
19 mm
19C050PG2L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
50PSI (344.74kPa)
0 mV ~ 100 mV
-
No Port
150PSI (1034.21kPa)
19 mm
19C050PG5K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
50PSI (344.74kPa)
0 mV ~ 100 mV (10V)
Male - 1/4" (6.35mm) NPT
Threaded
150PSI (1034.21kPa)
19 mm
19C100PA8K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Absolute
100PSI (689.48kPa)
0 mV ~ 100 mV (10V)
-
No Port
300PSI (2068.43kPa)
19 mm
19U050PA1K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
-
Absolute
50PSI (344.74kPa)
0 mV ~ 40 mV (5V)
Cell w/Body O-Ring
No Port
150PSI (1034.21kPa)
19 mm
19U500PA5K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
-
Absolute
500PSI (3447.38kPa)
0 mV ~ 40 mV (5V)
Male - 1/4" (6.35mm) NPT
Threaded
1200PSI (8273.71kPa)
19 mm
19C050PG8L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
50PSI (344.74kPa)
0 mV ~ 100 mV
-
No Port
150PSI (1034.21kPa)
19 mm
19C030PV5L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Board Mount
-
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vacuum
-30PSI (-206.84kPa)
0 mV ~ 100 mV
Male - 1/4" (6.35mm) NPT
Threaded
-90PSI (-620.53kPa)
19 mm
19C300PG3K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
300PSI (2068.43kPa)
0 mV ~ 100 mV (10V)
-
No Port
900PSI (6205.28kPa)
19 mm
19C003PG4L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
3PSI (20.68kPa)
0 mV ~ 100 mV
Male - 1/8" (3.18mm) NPT
Threaded
9PSI (62.0528kPa)
19 mm
19C500PG1K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
500PSI (3447.38kPa)
0 mV ~ 100 mV (10V)
Cell w/Body O-Ring
No Port
1200PSI (8273.71kPa)
19 mm
19C015PG8L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
15PSI (103.42kPa)
0 mV ~ 100 mV
-
No Port
45PSI (310.26kPa)
19 mm
19C500PG2K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
500PSI (3447.38kPa)
0 mV ~ 100 mV (10V)
-
No Port
1200PSI (8273.71kPa)
19 mm
19C100A2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Board Mount
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Absolute
100PSI (689.48kPa)
0 mV ~ 100 mV (10V)
-
No Port
300PSI (2068.43kPa)
19 mm
19C100PA3K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
15V
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Absolute
100PSI (689.48kPa)
0 mV ~ 100 mV (10V)
-
No Port
300PSI (2068.43kPa)
19 mm
19C100PG2L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
100PSI (689.48kPa)
0 mV ~ 100 mV
-
No Port
300PSI (2068.43kPa)
19 mm
19C300PG2L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Vented Gauge
300PSI (2068.43kPa)
0 mV ~ 100 mV
-
No Port
900PSI (6205.28kPa)
19 mm
19U100PA7K
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Board Mount
15V
-40°C ~ 125°C
Cylinder, Threaded
Analog Voltage
±0.25%
Flex Cable
-
Absolute
100PSI (689.48kPa)
0 mV ~ 40 mV (5V)
Male - 1/4" (6.35mm) BSPP
Threaded
300PSI (2068.43kPa)
19 mm
19C015PA2L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-40°C ~ 125°C
Cylinder
Analog Voltage
±0.25%
Flex Cable
Temperature Compensated
Absolute
15PSI (103.42kPa)
0 mV ~ 100 mV
-
No Port
45PSI (310.26kPa)
19 mm

About  Pressure Sensors, Transducers

Pressure sensors or transducers play a crucial role in detecting and accurately responding to the presence or variations in applied force. These devices are specifically designed to measure different types of pressure, including Absolute, Compound, Differential, Gauge, Sealed Gauge, Switch, Vacuum, and Vented Gauge. They are capable of operating within a wide range of pressures, spanning from -100PSI (-689.48kPa) to 20000PSI (137895.15kPa). Absolute pressure sensors are engineered to measure pressure relative to a perfect vacuum, providing an accurate indication of the absolute pressure at a given point. Compound pressure sensors, on the other hand, are designed to measure both positive and negative pressures, making them suitable for applications where pressure variations can occur in either direction. Differential pressure sensors are utilized to determine the difference in pressure between two points, enabling the measurement of pressure variances across various systems and components. Gauge pressure sensors, on the other hand, measure pressure relative to atmospheric pressure, providing an indication of the pressure above or below atmospheric levels. Sealed gauge pressure sensors are specifically designed to reference pressure against a fixed reference point, ensuring accurate measurements relative to a specific atmospheric pressure or another predetermined reference pressure. Switch pressure sensors are equipped with a threshold mechanism that triggers a response when the pressure exceeds or falls below a predefined set value, making them ideal for applications requiring pressure-based control or alarm systems. Vacuum pressure sensors are engineered to measure pressures below atmospheric levels, while vented gauge pressure sensors provide accurate measurements relative to a reference pressure, typically vented to atmospheric conditions. These pressure sensors or transducers are essential components used in a wide range of industries and applications, including manufacturing, automotive, aerospace, and process control. They contribute to the precise monitoring, control, and safety of systems by delivering accurate pressure measurements, facilitating efficient operation and preventing potential issues caused by excessive or insufficient pressure. In summary, pressure sensors or transducers are designed to detect and respond to force variations. They encompass various pressure types and operate within a broad pressure range, catering to diverse industrial applications. These sensors play a pivotal role in ensuring accurate pressure measurements, enabling efficient system operation and enhancing safety in numerous industries.