EE20-10.5 Series, Power Transformers

Results:
6
Manufacturer
Series
Current - Output (Max)
Voltage - Secondary (Full Load)
Voltage - Isolation
Voltage - Primary
Center Tap
Termination Style
Secondary Winding(s)
Height - Seated (Max)
Mounting Type
Size / Dimension
Weight
Primary Winding(s)
Type
Power - Max
Results remaining6
Applied Filters:
EE20-10.5
Select
ImageProduct DetailPriceAvailabilityECAD ModelTypeMounting TypeVoltage - PrimaryTermination StyleCurrent - Output (Max)WeightHeight - Seated (Max)Voltage - Secondary (Full Load)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSeriesSize / DimensionVoltage - Isolation
BV201S06006
115V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
115V
PC Pin
100mA
-
0.768" (19.50mm)
6V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
2800Vrms
BV201S12006
115V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
115V
PC Pin
50mA
-
0.768" (19.50mm)
12V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
2800Vrms
BV202S12006
230V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
230V
PC Pin
50mA
-
0.768" (19.50mm)
12V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
4200Vrms
BV201S24006
115V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
115V
PC Pin
25mA
-
0.768" (19.50mm)
24V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
2800Vrms
BV202S24006
230V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
230V
PC Pin
25mA
-
0.768" (19.50mm)
24V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
4200Vrms
BV202S06006
230V INPUT 0.6VA ENCAPSULATED TR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
230V
PC Pin
100mA
-
0.768" (19.50mm)
6V
Single
Single
No
0.6VA
EE20-10.5
24.00mm L x 23.00mm W
4200Vrms

Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.