HZ4 Series, Power Transformers

Results:
20
Manufacturer
Series
Power - Max
Voltage - Primary
Size / Dimension
Primary Winding(s)
Voltage - Secondary (Full Load)
Center Tap
Height - Seated (Max)
Voltage - Isolation
Termination Style
Secondary Winding(s)
Mounting Type
Weight
Current - Output (Max)
Type
Results remaining20
Applied Filters:
HZ4
Select
ImageProduct DetailPriceAvailabilityECAD ModelTypeMounting TypeTermination StyleVoltage - PrimaryVoltage - IsolationCurrent - Output (Max)WeightPower - MaxVoltage - Secondary (Full Load)Primary Winding(s)Secondary Winding(s)Center TapSize / DimensionHeight - Seated (Max)Series
HZP4X7500
7.5KVA 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
7500VA
120V, 115V, 110V
Dual
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X7500R
7.5KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
7500VA
240V
Single
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X5000R
5KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
5000VA
240V
Single
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X5000A
5KVA 230/460/575-120/95 4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
5000VA
115V, 95V
Dual, Multiple Taps
Single
Yes
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X5000
5KVA 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
5000VA
120V, 115V, 110V
Dual
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X3000R
3KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
3000VA
240V
Single
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X3000A
3KVA 230/460/575-120/95 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
3000VA
115V, 95V
Dual, Multiple Taps
Single
Yes
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X3000
3KVA HZ 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
3000VA
120V, 115V, 110V
Dual
Single
No
355.60mm L x 228.60mm W
431.80mm
HZ4
HZP4X2000A
2KVA 230/460/575-120/95 4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
2000VA
115V, 95V
Dual, Multiple Taps
Single
Yes
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X2000
2KVA 240/480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
2000VA
120V, 115V, 110V
Dual
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X2000R
2KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
2000VA
240V
Single
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1500A
1.5KVA 230/460/575-120/95 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
1500VA
115V, 95V
Dual, Multiple Taps
Single
Yes
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1500R
1.5KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
1500VA
240V
Single
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1000A
1KVA 230/460/575-115/95 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
1000VA
115V, 95V
Dual, Multiple Taps
Single
Yes
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1000R
1KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
1000VA
240V
Single
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1500
1.5KVA 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
1500VA
120V, 115V, 110V
Dual
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X1000
1KVA 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
1000VA
120V, 115V, 110V
Dual
Single
No
254.00mm L x 177.80mm W
304.80mm
HZ4
HZP4X10000
10KVA 240X480-120 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
240V, 480V
-
-
-
10000VA
120V, 115V, 110V
Dual
Single
No
431.80mm L x 304.80mm W
431.80mm
HZ4
HZP4X10000R
10KVA 480-240 50/60HZ N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
480V
-
-
-
10000VA
240V
Single
Single
No
431.80mm L x 304.80mm W
431.80mm
HZ4
HZP4X7500A
7.5KVA 230/460/575-115/95 N4X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
Wire Leads
230V, 460V, 575V
-
-
-
7500VA
115V, 95V
Dual, Multiple Taps
Single
Yes
355.60mm L x 228.60mm W
431.80mm
HZ4

About  Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.