269 Series, Power Transformers

Results:
5
Manufacturer
Series
Current - Output (Max)
Power - Max
Voltage - Secondary (Full Load)
Weight
Size / Dimension
Center Tap
Termination Style
Secondary Winding(s)
Height - Seated (Max)
Voltage - Isolation
Voltage - Primary
Mounting Type
Primary Winding(s)
Type
Results remaining5
Applied Filters:
269
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleVoltage - PrimaryVoltage - IsolationWeightTypeVoltage - Secondary (Full Load)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSize / DimensionHeight - Seated (Max)SeriesCurrent - Output (Max)
269EX
PWR XFMR LAMINATED 43VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
2000Vrms
1.8 lbs (816.5 g)
Laminated Core
380V, 6.3V
Single
Dual
Yes
43VA
55.63mm L x 66.80mm W
66.80mm
269
71mA, 2.5A
269GX
PWR XFMR LAMINATED 48VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
2000Vrms
1.9 lbs (861.8 g)
Laminated Core
450V, 6.3V
Single
Dual
Yes
48VA
55.63mm L x 66.80mm W
66.80mm
269
75mA, 2.5A
269BX
PWR XFMR LAMINATED 38VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
2000Vrms
1.6 lbs (725.7 g)
Laminated Core
300V, 6.3V
Single
Dual
Yes
38VA
55.63mm L x 63.50mm W
66.80mm
269
86mA, 2A
269JX
PWR XFMR LAMINATED 50VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
2000Vrms
1.9 lbs (861.8 g)
Laminated Core
500V, 6.3V
Single
Dual
Yes
50VA
55.63mm L x 66.80mm W
66.80mm
269
69mA, 2.5A
269AX
PWR XFMR LAMINATED 40VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
2000Vrms
1.6 lbs (725.7 g)
Laminated Core
250V, 6.3V
Single
Dual
Yes
40VA
55.63mm L x 63.50mm W
66.80mm
269
115mA, 2A

About  Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.