Universal Series, Power Transformers

Results:
7
Manufacturer
Series
Height - Seated (Max)
Size / Dimension
Weight
Current - Output (Max)
Voltage - Secondary (Full Load)
Power - Max
Center Tap
Secondary Winding(s)
Voltage - Primary
Primary Winding(s)
Termination Style
Voltage - Isolation
Mounting Type
Type
Results remaining7
Applied Filters:
Universal
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleVoltage - PrimaryVoltage - IsolationWeightSeriesTypeVoltage - Secondary (Full Load)Current - Output (Max)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSize / DimensionHeight - Seated (Max)
F-94X
PWR XFMR LAMINATED CHASSIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
1500Vrms
0.5 lb (226.8 g)
Universal
Laminated Core
40V, 20V, 10V
35mA
Single, Multiple Taps
Single
Yes
Varies
60.33mm L x 34.93mm W
34.93mm
F-361U
PWR XFMR LAMINATED 108VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V, 230V
1500Vrms
5.7 lbs (2.6 kg)
Universal
Laminated Core
24V, 27V, 30V, 33V, 36V
3A
Dual
Single, Multiple Taps
No
108VA
79.38mm L x 82.55mm W
95.25mm
F-91X
PWR XFMR LAMINATED CHASSIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
1500Vrms
1.5 lbs (680.4 g)
Universal
Laminated Core
40V, 20V, 10V
300mA
Single, Multiple Taps
Single
Yes
Varies
93.65mm L x 50.80mm W
57.94mm
F-360U
PWR XFMR LAMINATED 78VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V, 230V
1500Vrms
3.5 lbs (1.6 kg)
Universal
Laminated Core
6.5V, 13V, 19.5V, 26V
3A
Dual
Single
Yes
78VA
71.42mm L x 66.68mm W
85.73mm
F-92A
PWR XFMR LAMINATED CHASSIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
1500Vrms
3.3 lbs (1.5 kg)
Universal
Laminated Core
10V, 20V, 40V
750mA
Single, Multiple Taps
Single, Multiple Taps
No
Varies
63.50mm L x 76.20mm W
76.20mm
F-93X
PWR XFMR LAMINATED CHASSIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
1500Vrms
2.4 lbs (1.1 kg)
Universal
Laminated Core
10V, 20V, 40V
750mA
Single, Multiple Taps
Single, Multiple Taps
No
Varies
101.60mm L x 57.15mm W
66.04mm
F-90X
PWR XFMR LAMINATED CHASSIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
115V
1500Vrms
0.7 lb (317.51 g)
Universal
Laminated Core
10V, 20V, 40V
100mA
Single, Multiple Taps
Single, Multiple Taps
No
Varies
71.42mm L x 41.28mm W
41.28mm

Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.