Toroidal Medical, VPM Series, Power Transformers

Results:
49
Manufacturer
Series
Current - Output (Max)
Weight
Size / Dimension
Power - Max
Height - Seated (Max)
Voltage - Secondary (Full Load)
Voltage - Primary
Center Tap
Termination Style
Secondary Winding(s)
Voltage - Isolation
Mounting Type
Primary Winding(s)
Type
Results remaining49
Applied Filters:
Toroidal Medical, VPM
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleWeightVoltage - IsolationSeriesTypeVoltage - PrimaryVoltage - Secondary (Full Load)Current - Output (Max)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSize / DimensionHeight - Seated (Max)
VPM24-1040
PWR XFMR TORO 25VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.1 lbs (499 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 12V, Series 24V
Parallel 2.08A, Series 1.04A
Dual, Multiple Taps
Dual
No
25VA
84.00mm Dia
37.00mm
VPM12-2080
PWR XFMR TORO 25VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.1 lbs (499 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 6V, Series 12V
Parallel 4.16A, Series 2.08A
Dual, Multiple Taps
Dual
No
25VA
84.00mm Dia
37.00mm
VPM36-1390
PWR XFMR TORO 50VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.1 lbs (499 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 18V, Series 36V
Parallel 2.78A, Series 1.39A
Dual, Multiple Taps
Dual
No
50VA
92.00mm Dia
38.00mm
VPM240-210
PWR XFMR TORO 50VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.6 lbs (725.7 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 120V, Series 240V
Parallel 420mA, Series 210mA
Dual, Multiple Taps
Dual
No
50VA
92.00mm Dia
38.00mm
VPM48-2080
PWR XFMR TORO 100VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
2.7 lbs (1.2 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 24V, Series 48V
Parallel 4.16A, Series 2.08A
Dual, Multiple Taps
Dual
No
100VA
96.00mm Dia
52.00mm
VPM24-6670
PWR XFMR TORO 160VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
4 lbs (1.8 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 12V, Series 24V
Parallel 13.34A, Series 6.67A
Dual, Multiple Taps
Dual
No
160VA
113.00mm Dia
52.00mm
VPM18-13800
PWR XFMR TORO 250VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
5.6 lbs (2.5 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 9V, Series 18V
Parallel 27.6A, Series 13.8A
Dual, Multiple Taps
Dual
No
250VA
123.00mm Dia
60.00mm
VPM240-12500
PWR XFMR TORO 3000VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
56 lbs (25.4 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
208V, 240V
Parallel 120V, Series 240V
Parallel 25A, Series 12.5A
Dual, Multiple Taps
Dual
No
3000VA
222.00mm Dia
130.00mm
VPM48-20830
PWR XFMR TORO 1000VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
19 lbs (8.6 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 24V, Series 48V
Parallel 41.66A, Series 20.83A
Dual, Multiple Taps
Dual
No
1000VA
183.00mm Dia
74.00mm
VPM100-25000
PWR XFMR TORO 2500VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
44 lbs (20 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 50V, Series 100V
Parallel 50A, Series 25A
Dual, Multiple Taps
Dual
No
2500VA
215.00mm Dia
120.00mm
VPM18-1390
PWR XFMR TORO 25VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.1 lbs (499 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 9V, Series 18V
Parallel 2.78A, Series 1.39A
Dual, Multiple Taps
Dual
No
25VA
84.00mm Dia
37.00mm
VPM48-1040
PWR XFMR TORO 50VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
1.6 lbs (725.7 g)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 24V, Series 48V
Parallel 2.08A, Series 1.04A
Dual, Multiple Taps
Dual
No
50VA
92.00mm Dia
38.00mm
VPM240-670
PWR XFMR TORO 160VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
4 lbs (1.8 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 120V, Series 240V
Parallel 1.33A, Series 670mA
Dual, Multiple Taps
Dual
No
160VA
113.00mm Dia
52.00mm
VPM240-1040
PWR XFMR TORO 250VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
5.6 lbs (2.5 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 120V, Series 240V
Parallel 2.08A, Series 1.04A
Dual, Multiple Taps
Dual
No
250VA
123.00mm Dia
60.00mm
VPM48-10400
PWR XFMR TORO 500VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
10 lbs (4.5 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 24V, Series 48V
Parallel 20.8A, Series 10.4A
Dual, Multiple Taps
Dual
No
500VA
147.00mm Dia
64.00mm
VPM100-10000
PWR XFMR TORO 1000VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
44 lbs (20 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 50V, Series 100V
Parallel 20A, Series 10A
Dual, Multiple Taps
Dual
No
1000VA
183.00mm Dia
74.00mm
VPM240-10400
PWR XFMR TORO 2500VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
47 lbs (21.3 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 120V, Series 240V
Parallel 21.8A, Series 10.4A
Dual, Multiple Taps
Dual
No
2500VA
215.00mm Dia
120.00mm
VPM240-15600
PWR XFMR TORO 3750VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
67 lbs (30.4 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
208V, 240V
Parallel 120V, Series 240V
Parallel 31.2A, Series 15.6A
Dual, Multiple Taps
Dual
No
3750VA
235.00mm Dia
140.00mm
VPM240-20800
PWR XFMR TORO 5000VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
91 lbs (41.3 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
208V, 240V
Parallel 120V, Series 240V
Parallel 41.6A, Series 20.8A
Dual, Multiple Taps
Dual
No
5000VA
277.00mm Dia
140.00mm
VPM240-2080
PWR XFMR TORO 500VA CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
11 lbs (5 kg)
4000Vrms
Toroidal Medical, VPM
Toroidal
100V, 120V, 220V, 240V
Parallel 120V, Series 240V
Parallel 4.16A, Series 2.08A
Dual, Multiple Taps
Dual
No
500VA
147.00mm Dia
64.00mm

About  Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.