HT7 Series, Power Transformers

Results:
14
Manufacturer
Series
Current - Output (Max)
Power - Max
Secondary Winding(s)
Height - Seated (Max)
Voltage - Primary
Size / Dimension
Primary Winding(s)
Voltage - Secondary (Full Load)
Center Tap
Termination Style
Voltage - Isolation
Mounting Type
Weight
Type
Results remaining14
Applied Filters:
HT7
Select
ImageProduct DetailPriceAvailabilityECAD ModelTypeMounting TypeVoltage - PrimaryVoltage - IsolationWeightCurrent - Output (Max)Termination StyleSeriesVoltage - Secondary (Full Load)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSize / DimensionHeight - Seated (Max)
HTP7F9AS
XFORMER 9KVA 600D-208Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
600V
-
-
25A
Solder, Quick Connect
HT7
120V, 208V
Dual, Multiple Taps
Dual
Yes
9000VA
508.00mm L x 279.40mm W
431.80mm
HTP7F6AS
XFORMER 6KVA 600D-208Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
600V
-
-
16.6A
Solder, Quick Connect
HT7
120V, 208V
Dual, Multiple Taps
Dual
Yes
6000VA
406.40mm L x 228.60mm W
330.20mm
HTP79F6AS
XFORMER 6KVA 480D-380Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
480V
-
-
9.1A
Solder, Quick Connect
HT7
220V, 380V
Dual, Multiple Taps
Dual
Yes
6000VA
406.40mm L x 228.60mm W
330.20mm
HTP79F9AS
XFORMER 9KVA 480D-380Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
480V
-
-
13.6A
Solder, Quick Connect
HT7
220V, 380V
Dual, Multiple Taps
Dual
Yes
9000VA
508.00mm L x 279.40mm W
431.80mm
HTP79F3AS
XFORMER 3KVA 480D-380Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
480V
-
-
4.6A
Solder, Quick Connect
HT7
220V, 380V
Dual, Multiple Taps
Dual
Yes
3000VA
406.40mm L x 228.60mm W
330.20mm
HTP7F3AS
XFORMER 3KVA 600D-208Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
600V
-
-
8.3A
Solder, Quick Connect
HT7
120V, 208V
Dual, Multiple Taps
Dual
Yes
3000VA
406.40mm L x 228.60mm W
330.20mm
HTP7F45AS
45KVA 600D-208Y SS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
45000VA
-
-
HTP79F15AS
15KVA 480D-380Y SS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
15000VA
-
-
HTP71F9AS4X
9KVA 600D-480Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
9000VA
-
-
HTP71F6AS
6KVA 600D-480Y SS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
6000VA
-
-
HT7F6ASCU
6KVA 600D-208Y CU
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
600V
-
-
16.6A
Wire Leads
HT7
120V, 208V
Single, Multiple Taps
Single
Yes
6000VA
406.40mm L x 228.60mm W
330.20mm
HTP71F6AS4X
6KVA 600D-480Y 4X 304 ANSI 61
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
6000VA
-
-
HT71F3AS
3KVA 600D-480Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
3000VA
-
-
HTP7F30AS
30KVA 600-208Y SS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Chassis Mount
-
-
-
-
Wire Leads
HT7
-
-
-
-
30000VA
-
-

About  Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.