DMPC Series, Power Transformers

Results:
4
Manufacturer
Series
Current - Output (Max)
Height - Seated (Max)
Size / Dimension
Weight
Power - Max
Voltage - Secondary (Full Load)
Center Tap
Termination Style
Secondary Winding(s)
Voltage - Isolation
Voltage - Primary
Mounting Type
Primary Winding(s)
Type
Results remaining4
Applied Filters:
DMPC
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeVoltage - PrimaryTermination StyleVoltage - IsolationWeightSeriesTypeVoltage - Secondary (Full Load)Current - Output (Max)Primary Winding(s)Secondary Winding(s)Center TapPower - MaxSize / DimensionHeight - Seated (Max)
DMPC-Y-15
PWR XFMR LAMINATED 24VA TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
115V, 230V
PC Pin
1500Vrms
0.75 lb (340.19 g)
DMPC
Laminated Core
Parallel 5V, Series 15V
Parallel 360mA, Series 130mA
Dual
Dual
Yes
24VA
41.30mm L x 57.20mm W
34.90mm
DMPC-Y-12
PWR XFMR LAMINATED 24VA TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
115V, 230V
PC Pin
1500Vrms
0.75 lb (340.19 g)
DMPC
Laminated Core
Parallel 5V, Series 12V
Parallel 835mA, Series 150mA
Dual
Dual
Yes
24VA
41.30mm L x 57.20mm W
34.90mm
DMPC-X-15
PWR XFMR LAMINATED 10VA TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
115V, 230V
PC Pin
1500Vrms
0.56 lb (254.01 g)
DMPC
Laminated Core
Parallel 5V, Series 15V
Parallel 360mA, Series 50mA
Dual
Dual
Yes
10VA
47.60mm L x 36.50mm W
41.70mm
DMPC-X-12
PWR XFMR LAMINATED 10VA TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
115V, 230V
PC Pin
1500Vrms
0.56 lb (254.01 g)
DMPC
Laminated Core
Parallel 5V, Series 12V
Parallel 360mA, Series 60mA
Dual
Dual
Yes
10VA
47.60mm L x 36.50mm W
41.70mm

Power Transformers

The power transformers family consists of products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. These transformers are characterized by the presence of galvanically isolated primary and secondary windings, which facilitate the transfer of electrical power between two circuits without a direct electrical connection. It is important to note that these transformers are not packaged or equipped with the common connectors that are typically used in AC utility powered products. As such, they are not intended to be used as end-use products in an isolation transformer capacity. Instead, these transformers serve as key components in larger systems or products that require precise voltage regulation, isolation, and conversion. Power transformers play a crucial role in a wide range of applications, including power distribution systems, industrial machinery, and electronic equipment. They are utilized to step up or step down the voltage of AC power to match the requirements of specific systems or devices. By providing galvanic isolation between primary and secondary circuits, power transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. In summary, the power transformers family includes products that are specifically designed for the transformation of AC utility power at nominal frequencies of 400 Hz or less. They contain galvanically isolated primary and secondary windings and are not packaged or equipped with connectors for end-use purposes. Instead, they serve as critical components in larger systems that require precision voltage regulation, isolation, and conversion.