R02 Series, Power Relays, Over 2 Amps

Results:
29
Manufacturer
Series
Coil Voltage
Contact Form
Features
Operating Temperature
Termination Style
Switching Voltage
Contact Rating (Current)
Coil Current
Approval Agency
Load - Max Switching
Mounting Type
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Operate Time
Contact Material
Release Time
Must Operate Voltage
Coil Type
Results remaining29
Applied Filters:
R02
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeFeaturesCoil TypeContact MaterialOperating TemperatureApproval AgencyTermination StyleCoil VoltageContact FormContact Rating (Current)Switching VoltageSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeRelay TypeCoil CurrentLoad - Max SwitchingSeries
R02-14D10-12
RELAY GEN PURPOSE 3PDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 11 Pin (Octal)
12VDC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-240
RELAY GEN PURPOSE 3PDT 10A 240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
240VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-120H
RELAY GEN PURPOSE 3PDT 10A 120V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
120VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-6
RELAY GEN PURPOSE 3PDT 10A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
6VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-110H
RELAY GEN PURPOSE DPDT 10A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
110VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-12H
RELAY GEN PURPOSE DPDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
12VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14D10-110
RELAY GEN PURPOSE 3PDT 10A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 11 Pin (Octal)
110VDC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14D10-48
RELAY GEN PURPOSE 3PDT 10A 48V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 11 Pin (Octal)
48VDC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-24B
RELAY GEN PURPOSE 3PDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Test Button
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
24VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14D10-6
RELAY GEN PURPOSE 3PDT 10A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 11 Pin (Octal)
6VDC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11A10-24H
RELAY GEN PURPOSE DPDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 8 Pin (Octal)
24VAC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-48
RELAY GEN PURPOSE DPDT 10A 48V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
48VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14D10-12B
RELAY GEN PURPOSE 3PDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Test Button
-
-
-10°C ~ 60°C
-
Plug In, 11 Pin (Octal)
12VDC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-110
RELAY GEN PURPOSE DPDT 10A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
110VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-24
RELAY GEN PURPOSE 3PDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
24VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11A10-24
RELAY GEN PURPOSE DPDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 8 Pin (Octal)
24VAC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11A10-12
RELAY GEN PURPOSE DPDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 50°C
-
Plug In, 8 Pin (Octal)
12VAC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-6
RELAY GEN PURPOSE DPDT 10A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
6VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-14A10-6M
RELAY GEN PURPOSE 3PDT 10A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Mechanical Indicator
-
-
-10°C ~ 50°C
-
Plug In, 11 Pin (Octal)
6VAC
3PDT (3 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02
R02-11D10-12
RELAY GEN PURPOSE DPDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-10°C ~ 60°C
-
Plug In, 8 Pin (Octal)
12VDC
DPDT (2 Form C)
10 A
-
-
-
-
-
25 ms
20 ms
General Purpose
-
-
R02

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.