Harmony Series, Power Relays, Over 2 Amps

Results:
398
Manufacturer
Series
Coil Current
Must Operate Voltage
Must Release Voltage
Coil Voltage
Switching Voltage
Contact Rating (Current)
Termination Style
Operating Temperature
Operate Time
Release Time
Contact Form
Contact Material
Mounting Type
Load - Max Switching
Features
Seal Rating
Relay Type
Coil Insulation
Coil Type
Approval Agency
Results remaining398
Applied Filters:
Harmony
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesMounting TypeTermination StyleApproval AgencyContact FormOperating TemperatureCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max SwitchingSeries
RSL1AB4JD
HARMONY, SLIM INTERFACE PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
PC Pin
-
SPDT (1 Form C)
-40°C ~ 55°C
12VDC
6 A
277VAC - Max
14.2 mA
Non Latching
-
-
9 VDC
0.6 VDC
12 ms
5 ms
Silver Tin Oxide (AgSnO)
General Purpose
-
Harmony
RXG21E7
HARMONY, INTERFACE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 70°C
48VAC
5 A
250VAC, 30VDC - Max
-
Non Latching
-
-
38.4 VAC
14.4 VAC
20 ms
20 ms
Silver Tin Oxide Indium Oxide (AgSnOInO)
General Purpose
-
Harmony
RXM2AB2FD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator, Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
110VDC
12 A
250VAC, 28VDC - Max
8.2 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM2AB2E7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator, Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
48VAC
12 A
250VAC, 28VDC - Max
67.6 mA
Non Latching
-
-
38.4 VAC
7.2 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM2AB2F7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator, Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
120VAC
10 A
250VAC, 28VDC - Max
27.1 mA
Non Latching
-
-
96 VAC
18 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM2AB2B7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator, Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
24VAC
10 A
250VAC, 28VDC - Max
133.3 mA
Non Latching
-
-
19.2 VAC
3.6 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM2AB2P7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator, Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
230VAC
10 A
250VAC, 28VDC - Max
15.3 mA
Non Latching
-
-
184 VAC
34.5 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4AB1P7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
230VAC
6 A
250VAC, 28VDC - Max
15.3 mA
Non Latching
-
-
184 VAC
34.5 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4GB1BD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
24VDC
3 A
250VAC, 28VDC - Max
36.9 mA
Non Latching
-
-
19.2 VDC
2.4 VDC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony
RXM4GB1F7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
120VAC
3 A
250VAC, 28VDC - Max
33.1 mA
Non Latching
-
-
96 VAC
18 VAC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony
RXM4AB1FD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
110VDC
6 A
250VAC, 28VDC - Max
8.2 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM21BD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
24VDC
15 A
250VAC, 28VDC - Max
37.5 mA
Non Latching
-
-
19.2 VDC
2.4 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4GB1JD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
12VDC
3 A
250VAC, 28VDC - Max
75 mA
Non Latching
-
-
9.6 VDC
1.2 VDC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony
RXM4AB1U7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
240VAC
6 A
250VAC, 28VDC - Max
13.5 mA
Non Latching
-
-
192 VAC
36 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4GB1B7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
24VAC
3 A
250VAC, 28VDC - Max
133.3 mA
Non Latching
-
-
19.2 VAC
3.6 VAC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony
RPM21ED
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
48VDC
15 A
250VAC, 28VDC - Max
18.8 mA
Non Latching
-
-
38.4 VDC
4.8 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM21FD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
110VDC
15 A
250VAC, 28VDC - Max
8.2 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM21E7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
DPDT (2 Form C)
-40°C ~ 55°C
48VAC
15 A
250VAC, 28VDC - Max
67.8 mA
Non Latching
-
-
38.4 VAC
7.2 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4AB1ED
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
48VDC
6 A
250VAC, 28VDC - Max
18.8 mA
Non Latching
-
-
38.4 VDC
4.8 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4GB1E7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Test Button
Socketable
Plug In
-
4PDT (4 Form C)
-40°C ~ 55°C
48VAC
3 A
250VAC, 28VDC - Max
67.6 mA
Non Latching
-
-
38.4 VAC
7.2 VAC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.