Harmony Series, Power Relays, Over 2 Amps

Results:
398
Manufacturer
Series
Coil Current
Must Operate Voltage
Must Release Voltage
Coil Voltage
Switching Voltage
Contact Rating (Current)
Termination Style
Operating Temperature
Operate Time
Release Time
Contact Form
Contact Material
Mounting Type
Load - Max Switching
Features
Seal Rating
Relay Type
Coil Insulation
Coil Type
Approval Agency
Results remaining398
Applied Filters:
Harmony
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApproval AgencyTermination StyleOperating TemperatureFeaturesCoil VoltageContact FormContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max SwitchingSeries
RUMC31B7
RLY 3CO CYL PINS 10A@250V 24VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
Plug In
-40°C ~ 55°C
Test Button
24VAC
3PDT (3 Form C)
10 A
250VAC, 28VDC - Max
333.3 mA
Non Latching
-
-
19.2 VAC
3.6 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RUMC22F7
ZELIO RUM, UNIVERSAL PLUGIN RELA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator, Test Button
120VAC
DPDT (2 Form C)
10 A
250VAC, 28VDC - Max
70.6 mA
Non Latching
-
-
96 VAC
18 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM41FD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Test Button
110VDC
4PDT (4 Form C)
15 A
250VAC, 28VDC - Max
17.3 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM41F7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
120VAC
4PDT (4 Form C)
15 A
250VAC, 28VDC - Max
57.1 mA
Non Latching
-
-
96 VAC
18 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXG23P7
HARMONY, INTERFACE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 70°C
Lighted Indicator
230VAC
DPDT (2 Form C)
5 A
250VAC, 30VDC - Max
-
Non Latching
-
-
184 VAC
69 VAC
20 ms
20 ms
Silver Tin Oxide Indium Oxide (AgSnOInO)
General Purpose
-
Harmony
9AS3D12
ELECTROMECHNICAL POWER RELAYS, S
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
Quick Connect - 0.187"/0.250"
-40°C ~ 40°C
-
12VDC
SPST-NO (1 Form A)
30 A
277VAC, 28VDC - Max
77.4 mA
Non Latching
Sealed - Fully
-
9.6 VDC
1.2 VDC
20 ms
10 ms
Silver Alloy
General Purpose
-
Harmony
RPM41P7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Test Button
230VAC
4PDT (4 Form C)
15 A
250VAC, 28VDC - Max
31.3 mA
Non Latching
-
-
184 VAC
34.5 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM32JD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator, Test Button
12VDC
3PDT (3 Form C)
15 A
250VAC, 28VDC - Max
150 mA
Non Latching
-
-
9.6 VDC
1.2 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM32P7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator, Test Button
230VAC
3PDT (3 Form C)
15 A
250VAC, 28VDC - Max
24 mA
Non Latching
-
-
184 VAC
34.5 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXG12RD
RELAY 1CO 10A@250VAC 6VDC COIL L
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
Plug In
-40°C ~ 70°C
Lighted Indicator, Test Button
6VDC
SPDT (1 Form C)
10 A
250VAC, 30VDC - Max
88.2 mA
Non Latching
-
Class F
-
0.6 VDC
20 ms
20 ms
Silver Tin Oxide Indium Oxide (AgSnOInO)
General Purpose
-
Harmony
RXG23F7
HARMONY, INTERFACE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 70°C
Lighted Indicator
120VAC
DPDT (2 Form C)
5 A
250VAC, 30VDC - Max
-
Non Latching
-
-
-
36 VAC
20 ms
20 ms
Silver Tin Oxide Indium Oxide (AgSnOInO)
General Purpose
-
Harmony
RPM23FD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
110VDC
DPDT (2 Form C)
15 A
250VAC, 28VDC - Max
8.2 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4GB3FD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
110VDC
4PDT (4 Form C)
3 A
250VAC, 28VDC - Max
8.2 mA
Non Latching
-
-
88 VDC
11 VDC
20 ms
20 ms
Silver (Ag), Gold (Au)
General Purpose
-
Harmony
RXM4AB3B7
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
24VAC
4PDT (4 Form C)
5 A
250VAC, 28VDC - Max
133.3 mA
Non Latching
-
-
19.2 VAC
3.6 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM23P7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
230VAC
DPDT (2 Form C)
15 A
250VAC, 28VDC - Max
14.1 mA
Non Latching
-
-
184 VAC
34.5 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM23BD
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
24VDC
DPDT (2 Form C)
15 A
250VAC, 28VDC - Max
37.5 mA
Non Latching
-
-
19.2 VDC
2.4 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM23B7
PLUG IN RELAY, ZELIO RELAY, POWE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
24VAC
DPDT (2 Form C)
15 A
250VAC, 28VDC - Max
135.6 mA
Non Latching
-
-
19.2 VAC
3.6 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RPM23F7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
120VAC
DPDT (2 Form C)
15 A
250VAC, 28VDC - Max
27.1 mA
Non Latching
-
-
96 VAC
18 VAC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM4AB3BD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator
24VDC
4PDT (4 Form C)
5 A
250VAC, 28VDC - Max
36.9 mA
Non Latching
-
-
19.2 VDC
2.4 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony
RXM2AB2BD
HARMONY, MINIATURE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
-
Plug In
-40°C ~ 55°C
Lighted Indicator, Test Button
24VDC
DPDT (2 Form C)
10 A
250VAC, 28VDC - Max
36.9 mA
Non Latching
-
-
19.2 VDC
2.4 VDC
20 ms
20 ms
Silver Nickel (AgNi)
General Purpose
-
Harmony

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.