Harmony Series, Power Relays, Over 2 Amps

Results:
398
Manufacturer
Series
Coil Current
Must Operate Voltage
Must Release Voltage
Coil Voltage
Switching Voltage
Contact Rating (Current)
Termination Style
Operating Temperature
Operate Time
Release Time
Contact Form
Contact Material
Mounting Type
Load - Max Switching
Features
Seal Rating
Relay Type
Coil Insulation
Coil Type
Approval Agency
Results remaining398
Applied Filters:
Harmony
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeFeaturesOperating TemperatureCoil TypeTermination StyleContact MaterialApproval AgencyContact FormCoil VoltageSwitching VoltageSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageRelay TypeCoil CurrentContact Rating (Current)Operate TimeRelease TimeLoad - Max SwitchingSeries
RXM2LB1F7
MINIATURE RELAY 5A 2CO 120VAC W/
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
RXM2LB1BD
MINIATURE RELAY 5A 2CO 24VDC W/O
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
RXM2LB1P7
MINIATURE RELAY 5A 2CO 230VAC W/
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
RXM2LB1JD
MINIATURE RELAY 5A 2CO 12VDC W/O
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
RXM2LB2BD
MINIATURE RELAY 5A 2CO 24VDC WIT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
725AXXBC3ML-240A
725 POWER RELAY, 1 NO, 30A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Harmony
RSL1AB4BD
HARMONY, SLIM INTERFACE PLUG-IN
1+
$18.0000
5+
$17.0000
10+
$16.0000
Quantity
40 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Socketable
-
-40°C ~ 55°C
Non Latching
Plug In
Silver Tin Oxide (AgSnO)
-
SPDT (1 Form C)
24VDC
277VAC - Max
-
-
18 VDC
1.2 VDC
General Purpose
7.1 mA
6 A
12 ms
5 ms
-
Harmony
RSL1PVBU
HARMONY, SLIM INTERFACE RELAY PR
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
Lighted Indicator
-40°C ~ 55°C
Non Latching
Screw Terminal
Silver Tin Oxide (AgSnO)
-
SPDT (1 Form C)
24VDC
277VAC - Max
-
-
-
1.2 VDC
General Purpose
7.1 mA
6 A
12 ms
5 ms
-
Harmony
RSB2A080M7PV
HARMONY, INTERFACE PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Lighted Indicator
-40°C ~ 70°C
Non Latching
Screw Terminal
Silver Nickel (AgNi)
-
DPDT (2 Form C)
220VAC
250VAC, 28VDC - Max
-
-
176 VAC
33 VAC
General Purpose
7.3 mA
8 A
20 ms
20 ms
2000VA, 224W
Harmony
RUMC33BD
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Lighted Indicator
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
3PDT (3 Form C)
24VDC
250VAC, 28VDC - Max
-
-
19.2 VDC
2.4 VDC
General Purpose
51.1 mA
10 A
20 ms
20 ms
-
Harmony
RUMC21F7
RELAY 2CO CYL PINS 10A@250V 120V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
120VAC
250VAC, 28VDC - Max
-
-
96 VAC
18 VAC
General Purpose
70.6 mA
10 A
20 ms
20 ms
-
Harmony
RPF2AP7
HARMONY, POWER RELAY, DIN RAIL/P
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
-40°C ~ 55°C
Non Latching
Quick Connect - Multiple Sizes
Silver Tin Oxide (AgSnO)
-
DPST-NO (2 Form A)
230VAC
250VAC, 28VDC - Max
-
-
-
34.5 VAC
General Purpose
14.7 mA
25 A
25 ms
25 ms
-
Harmony
RUMC21P7
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Lighted Indicator
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
230VAC
250VAC, 28VDC - Max
-
-
184 VAC
34.5 VAC
General Purpose
33.8 mA
10 A
20 ms
20 ms
-
Harmony
RUMC21B7
RLY 2CO CYL PINS 10A@250V 24VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
24VAC
250VAC, 28VDC - Max
-
-
19.2 VAC
3.6 VAC
General Purpose
333.3 mA
10 A
20 ms
20 ms
-
Harmony
RUMF21BD
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
24VDC
250VAC, 28VDC - Max
-
-
19.2 VDC
2.4 VDC
General Purpose
51.1 mA
10 A
20 ms
20 ms
-
Harmony
RPM43F7
HARMONY, POWER PLUG-IN RELAY, 15
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Lighted Indicator
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
4PDT (4 Form C)
120VAC
250VAC, 28VDC - Max
-
-
96 VAC
18 VAC
General Purpose
57.1 mA
15 A
20 ms
20 ms
-
Harmony
RUMC21BD
RLY 2CO CYL PINS 10A@250V 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
24VDC
250VAC, 28VDC - Max
-
-
19.2 VDC
2.4 VDC
General Purpose
51.1 mA
10 A
20 ms
20 ms
-
Harmony
RUMC21FD
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
110VDC
250VAC, 28VDC - Max
-
-
88 VDC
11 VDC
General Purpose
15.1 mA
10 A
20 ms
20 ms
-
Harmony
RUMF21JD
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
12VDC
250VAC, 28VDC - Max
-
-
9.6 VDC
1.2 VDC
General Purpose
100 mA
10 A
20 ms
20 ms
-
Harmony
RUMF21F7
HARMONY, UNIVERSAL PLUG-IN RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
Test Button
-40°C ~ 55°C
Non Latching
Plug In
Silver Nickel (AgNi)
-
DPDT (2 Form C)
120VAC
250VAC, 28VDC - Max
-
-
96 VAC
18 VAC
General Purpose
70.6 mA
10 A
20 ms
20 ms
-
Harmony

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.