730 Series, Power Relays, Over 2 Amps

Results:
22
Manufacturer
Series
Coil Current
Coil Voltage
Termination Style
Contact Rating (Current)
Mounting Type
Contact Form
Operating Temperature
Switching Voltage
Approval Agency
Load - Max Switching
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Operate Time
Contact Material
Release Time
Must Operate Voltage
Features
Coil Type
Results remaining22
Applied Filters:
730
Select
ImageProduct DetailPriceAvailabilityECAD ModelCoil TypeSeriesMounting TypeOperating TemperatureApproval AgencyContact FormTermination StyleContact MaterialFeaturesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeRelay TypeLoad - Max Switching
730-2QR-110VAC
Kacon
RELAY GEN PURPOSE DPST 25A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
110VAC
25 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1TR-110VAC
RELAY GEN PURPOSE SPST 30A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
110VAC
30 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
730-1TB-220VAC
Kacon
RELAY GEN PURPOSE SPST 30A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
220VAC
30 A
277VAC, 30VDC - Max
11.8 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1TR-24VDC
Kacon
RELAY GEN PURPOSE SPST 30A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
24VDC
30 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2TR-24VDC
Kacon
RELAY GEN PURPOSE DPST 25A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Screw Terminal
Silver Alloy
Test Button
24VDC
25 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2TR-110VAC
Kacon
RELAY GEN PURPOSE DPST 25A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Screw Terminal
Silver Alloy
Test Button
110VAC
25 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2TB-110VAC
Kacon
RELAY GEN PURPOSE DPST 25A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Screw Terminal
Silver Alloy
Test Button
110VAC
25 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2TB-24VDC
Kacon
RELAY GEN PURPOSE DPST 25A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Screw Terminal
Silver Alloy
Test Button
24VDC
25 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2TB-220VAC
Kacon
RELAY GEN PURPOSE DPST 25A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Screw Terminal
Silver Alloy
Test Button
220VAC
25 A
277VAC, 30VDC - Max
11.8 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2QR-24VDC
Kacon
RELAY GEN PURPOSE DPST 25A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
24VDC
25 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1QR-110VAC
Kacon
RELAY GEN PURPOSE SPST 30A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
110VAC
30 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2QB-110VAC
Kacon
RELAY GEN PURPOSE DPST 25A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
110VAC
25 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2QB-24VDC
Kacon
RELAY GEN PURPOSE DPST 25A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
24VDC
25 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-2QB-220VAC
Kacon
RELAY GEN PURPOSE DPST 25A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
220VAC
25 A
277VAC, 30VDC - Max
11.8 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1TB-110VAC
Kacon
RELAY GEN PURPOSE SPST 30A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
110VAC
30 A
277VAC, 30VDC - Max
24.5 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1TB-24VDC
Kacon
RELAY GEN PURPOSE SPST 30A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
24VDC
30 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1TR-220VAC
Kacon
RELAY GEN PURPOSE SPST 30A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Screw Terminal
Silver Alloy
Test Button
220VAC
30 A
277VAC, 30VDC - Max
11.8 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1QB-24VDC
Kacon
RELAY GEN PURPOSE SPST 30A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
Panel Mount
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
24VDC
30 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1QR-24VDC
Kacon
RELAY GEN PURPOSE SPST 30A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
24VDC
30 A
277VAC, 30VDC - Max
79 mA
-
-
-
-
30 ms
30 ms
General Purpose
-
730-1QR-220VAC
Kacon
RELAY GEN PURPOSE SPST 30A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
730
DIN Rail
-10°C ~ 60°C
-
SPST-NO (1 Form A)
Quick Connect - 0.250" (6.3mm)
Silver Alloy
Test Button
220VAC
30 A
277VAC, 30VDC - Max
11.8 mA
-
-
-
-
30 ms
30 ms
General Purpose
-

Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.