13 Series, Power Relays, Over 2 Amps

Results:
13
Manufacturer
Series
Must Operate Voltage
Coil Voltage
Contact Rating (Current)
Load - Max Switching
Contact Form
Contact Material
Coil Type
Operating Temperature
Switching Voltage
Termination Style
Coil Current
Approval Agency
Mounting Type
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Operate Time
Release Time
Features
Results remaining13
Applied Filters:
13
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesMounting TypeOperating TemperatureTermination StyleApproval AgencyContact FormSeriesCoil VoltageContact Rating (Current)Switching VoltageCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageContact MaterialRelay TypeCoil CurrentOperate TimeRelease TimeLoad - Max Switching
13.01.8.125.0000
RELAY IMPULSE SPDT 16A 110-125V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
110 ~ 125VAC
16 A
400VAC - Max
Latching, Single Coil
-
-
-
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.01.0.012.0000
RELAY IMPULSE SPDT 16A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
12VAC/DC
16 A
400VAC - Max
Latching, Single Coil
-
-
10.8 VAC/DC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.31.9.024.4300
RELAY GEN PURPOSE SPST 12A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPST-NO (1 Form A)
13
24VDC
12 A
400VAC - Max
Non Latching
-
-
19.2 VDC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
4800VA
13.31.8.230.4300
RELAY GEN PURPOSE SPST 12A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPST-NO (1 Form A)
13
230VAC
12 A
400VAC - Max
Non Latching
-
-
184 VAC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
4800VA
13.01.0.024.0000T
RELAY IMPULSE SPDT 16A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
24VAC/DC
16 A
400VAC - Max
Latching, Single Coil
-
-
20.6 VAC/DC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.01.8.230.0000
RELAY IMPULSE SPDT 16A 230-240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
230 ~ 240VAC
16 A
400VAC - Max
Latching, Single Coil
-
-
-
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.01.0.024.0000
RELAY IMPULSE SPDT 16A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
24VAC/DC
16 A
400VAC - Max
Latching, Single Coil
-
-
20.6 VAC/DC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.12.0.024.0000
RELAY IMPULSE SPDT 8A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C) + SPST-NO (1 Form A)
13
24VAC/DC
8 A
400VAC - Max
Latching, Single Coil
-
-
19.2 VAC/DC
-
Silver Cadmium Oxide (AgCdO)
Impulse
-
-
-
3200VA
13.31.8.012.4300
RELAY GEN PURPOSE SPST 12A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPST-NO (1 Form A)
13
12VAC
12 A
400VAC - Max
Non Latching
-
-
9.6 VAC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
4800VA
13.81.8.230.0000
RELAY IMPULSE SPST 16A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPST-NO (1 Form A)
13
230VAC
16 A
400VAC - Max
Latching, Single Coil
-
-
184 VAC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.12.0.012.0000
RELAY IMPULSE SPDT 8A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C) + SPST-NO (1 Form A)
13
12VAC/DC
8 A
400VAC - Max
Latching, Single Coil
-
-
9.6 VAC/DC
-
Silver Cadmium Oxide (AgCdO)
Impulse
-
-
-
3200VA
13.01.0.012.0000T
RELAY IMPULSE SPDT 16A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
12VAC/DC
16 A
400VAC - Max
Latching, Single Coil
-
-
10.8 VAC/DC
-
Silver Tin Oxide (AgSnO)
Impulse
-
-
-
6400VA
13.11.8.230.0000
RELAY IMPULSE SPDT 12A 230-240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
DIN Rail
-10°C ~ 60°C
Screw Terminal
CE
SPDT (1 Form C)
13
230 ~ 240VAC
12 A
400VAC - Max
Latching, Single Coil
-
-
-
-
Silver Cadmium Oxide (AgCdO)
Impulse
-
-
-
4800VA

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.