V23008, AXICOM Series, Power Relays, Over 2 Amps

Results:
14
Manufacturer
Series
Coil Current
Coil Voltage
Contact Rating (Current)
Contact Form
Contact Material
Operating Temperature
Switching Voltage
Termination Style
Approval Agency
Load - Max Switching
Mounting Type
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Operate Time
Must Operate Voltage
Release Time
Features
Coil Type
Results remaining14
Applied Filters:
V23008, AXICOM
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesMounting TypeApproval AgencyContact FormTermination StyleOperating TemperatureSeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageContact MaterialRelay TypeOperate TimeRelease TimeLoad - Max Switching
1393800-3
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
230VAC
15 A
250VAC, 300VDC - Max
14.8 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
1393800-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
230VAC
15 A
250VAC, 300VDC - Max
14.8 mA
Non Latching
-
-
-
-
Silver (Ag)
General Purpose
-
-
-
1393800-8
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
24VAC
15 A
250VAC, 300VDC - Max
142 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
1-1393800-0
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
24VAC
8 A
250VAC, 300VDC - Max
142 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
1-1393800-4
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
110VAC
15 A
250VAC, 300VDC - Max
31 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
2-1393800-5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
42VAC
8 A
250VAC, 300VDC - Max
81 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
3-1393800-5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
24VAC
15 A
250VAC, 300VDC - Max
142 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
V23008A1015A100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
110VAC
8 A
250VAC, 300VDC - Max
31 mA
Non Latching
-
-
-
-
Silver (Ag)
General Purpose
-
-
-
1393800-5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
230VAC
8 A
250VAC, 300VDC - Max
14.8 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
1-1393800-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
12VAC
15 A
250VAC, 300VDC - Max
283 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
1-1393800-5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
110VAC
8 A
250VAC, 300VDC - Max
31 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
2-1393800-4
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
DPDT (2 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
42VAC
15 A
250VAC, 300VDC - Max
81 mA
Non Latching
-
-
-
-
Silver Nickel (AgNi)
General Purpose
-
-
-
V23008A1002A100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
230VAC
8 A
250VAC, 300VDC - Max
14.8 mA
Non Latching
-
-
-
-
Silver (Ag)
General Purpose
-
-
-
V23008A1005A100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Socketable
-
3PDT (3 Form C)
Plug In
-40°C ~ 65°C
V23008, AXICOM
24VAC
8 A
250VAC, 300VDC - Max
142 mA
Non Latching
-
-
-
-
Silver (Ag)
General Purpose
-
-
-

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.