S87R Series, Power Relays, Over 2 Amps

Results:
11
Manufacturer
Series
Coil Current
Coil Voltage
Must Operate Voltage
Contact Form
Operating Temperature
Switching Voltage
Termination Style
Contact Rating (Current)
Approval Agency
Load - Max Switching
Mounting Type
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Operate Time
Contact Material
Release Time
Features
Coil Type
Results remaining11
Applied Filters:
S87R
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeFeaturesContact FormTermination StyleOperating TemperatureSeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageContact MaterialRelay TypeOperate TimeRelease Time
S87R5A2B1D1-240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
240VAC
20 A
277VAC - Max
16.5 mA
Non Latching
-
Class B
204 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R11A2B1D1-24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPDT (2 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
24VAC
20 A
277VAC - Max
165 mA
Non Latching
-
Class B
20.4 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R5D2B1D1-24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
24VDC
20 A
277VAC - Max
120 mA
Non Latching
-
Class B
18 VDC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R11A2B1D1120
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPDT (2 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
120VAC
20 A
277VAC - Max
33 mA
Non Latching
-
Class B
102 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R11A2B1D1240
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPDT (2 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
240VAC
20 A
277VAC - Max
16.5 mA
Non Latching
-
Class B
204 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R5A2B1D1-120
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
120VAC
20 A
277VAC - Max
33 mA
Non Latching
-
Class B
102 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R5A2B1D1-24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
24VAC
20 A
277VAC - Max
165 mA
Non Latching
-
Class B
20.4 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R5D2B1D1-12
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
12VDC
20 A
277VAC - Max
240 mA
Non Latching
-
Class B
9 VDC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R7A2B1D1-24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPST-NO (2 Form A)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
24VAC
20 A
277VAC - Max
165 mA
Non Latching
-
Class B
20.4 VAC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R11D2B1D1-24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPDT (2 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
24VDC
20 A
277VAC - Max
188 mA
Non Latching
-
Class B
18 VDC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-
S87R11D2B1D1110
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
DPDT (2 Form C)
Quick Connect - 0.250" (6.3mm)
-10°C ~ 65°C
S87R
110VDC
20 A
277VAC - Max
40 mA
Non Latching
-
Class B
82.5 VDC
-
Silver Cadmium Oxide (AgCdO)
General Purpose
-
-

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.