PRCU Series, Power Relays, Over 2 Amps

Results:
13
Manufacturer
Series
Must Release Voltage
Coil Voltage
Must Operate Voltage
Coil Current
Operating Temperature
Contact Rating (Current)
Contact Form
Operate Time
Release Time
Switching Voltage
Termination Style
Approval Agency
Load - Max Switching
Mounting Type
Seal Rating
Relay Type
Coil Insulation
Contact Material
Features
Coil Type
Results remaining13
Applied Filters:
PRCU
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeApproval AgencyTermination StyleContact FormSeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max Switching
15924.2
RELAY GEN PURPOSE DPDT 8A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
DPDT (2 Form C)
PRCU
12VAC/DC
8 A
400VAC - Max
33.3 mA
Non Latching
-
-
9.6 VAC/DC
1.2 VAC/DC
7 ms
2 ms
Silver Nickel (AgNi)
General Purpose
-
15925.2
RELAY GEN PURPOSE DPDT 8A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
DPDT (2 Form C)
PRCU
24VAC/DC
8 A
400VAC - Max
16.7 mA
Non Latching
-
-
19.2 VAC/DC
2.4 VAC/DC
7 ms
2 ms
Silver Nickel (AgNi)
General Purpose
-
15509.2
RELAY GEN PURPOSE SPDT 6A 48V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
48VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
38.4 VAC/DC
4.8 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15510.2
RELAY GEN PURPOSE SPDT 6A 60V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
60VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
48 VAC/DC
6 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15926.2
RELAY GEN PURP DPDT 8A 230-240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
DPDT (2 Form C)
PRCU
230 ~ 240VAC/DC
8 A
400VAC - Max
-
Non Latching
-
-
-
-
7 ms
2 ms
Silver Nickel (AgNi)
General Purpose
-
15554.2
RELAY GEN PURPOSE SPDT 6A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
230VAC
6 A
400VAC - Max
-
Non Latching
-
-
184 VAC
23 VAC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15514.2
RELAY GEN PURPOSE SPDT 6A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
12VDC
6 A
400VAC - Max
-
Non Latching
-
-
9.6 VDC
0.6 VDC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15508.2
RELAY GEN PURPOSE SPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
24VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
19.2 VAC/DC
2.4 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15513.2
RELAY GEN PURPOSE SPDT 6A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
6VDC
6 A
400VAC - Max
-
Non Latching
-
-
4.8 VDC
0.3 VDC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15569.2
RELAY GEN PURPOSE SPDT 6A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
12VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
9.6 VAC/DC
1.2 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15512.2
RELAY GEN PURPOSE SPDT 6A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
230VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
184 VAC/DC
23 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15515.2
RELAY GEN PURPOSE SPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
24VDC
6 A
400VAC - Max
-
Non Latching
-
-
19.2 VDC
1.2 VDC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-
15511.2
RELAY GEN PURPOSE SPDT 6A 125V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
-
Screw Terminal
SPDT (1 Form C)
PRCU
125VAC/DC
6 A
400VAC - Max
-
Non Latching
-
-
100 VAC/DC
12.5 VAC/DC
5 ms
6 ms
Silver Nickel (AgNi)
General Purpose
-

Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.