DRR Series, Power Relays, Over 2 Amps

Results:
17
Manufacturer
Series
Coil Current
Must Release Voltage
Coil Voltage
Must Operate Voltage
Termination Style
Operating Temperature
Contact Rating (Current)
Approval Agency
Load - Max Switching
Mounting Type
Contact Form
Operate Time
Contact Material
Release Time
Features
Switching Voltage
Seal Rating
Relay Type
Coil Insulation
Coil Type
Results remaining17
Applied Filters:
DRR
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeContact FormTermination StyleOperating TemperatureApproval AgencySeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeFeaturesSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max Switching
1133760000
RELAY GEN PURPOSE DPDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
24VAC
10 A
250VAC - Max
130 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
19.2 VAC
7.2 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133360000
RELAY GEN PURPOSE DPDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
12VDC
10 A
250VAC - Max
125 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
9 VDC
1.8 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1132820000
RELAY GEN PURPOSE 3PDT 12A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
3PDT (3 Form C)
Screw Terminal
-40°C ~ 65°C
CE, cURus
DRR
-
12 A
250VAC - Max
-
Non Latching
-
-
-
-
-
-
-
-
General Purpose
3000VA
1133400000
RELAY GEN PURPOSE DPDT 10A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
220VDC
10 A
250VAC - Max
7.6 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
165 VDC
33 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133830000
RELAY GEN PURPOSE 3PDT 10A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
230VAC
10 A
250VAC - Max
14.9 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
184 VAC
69 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133820000
RELAY GEN PURPOSE 3PDT 10A 115V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
115VAC
10 A
250VAC - Max
29.8 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
92 VAC
34.5 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133430000
RELAY GEN PURPOSE 3PDT 10A 48V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
48VDC
10 A
250VAC - Max
29.2 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
36 VDC
7.2 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133410000
RELAY GEN PURPOSE 3PDT 10A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
12VDC
10 A
250VAC - Max
125 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
9 VDC
1.8 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133380000
RELAY GEN PURPOSE DPDT 10A 48V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
48VDC
10 A
250VAC - Max
29.2 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
36 VDC
7.2 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133420000
RELAY GEN PURPOSE 3PDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
24VDC
10 A
250VAC - Max
55.8 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
18 VDC
3.6 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133370000
RELAY GEN PURPOSE DPDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
24VDC
10 A
250VAC - Max
55.8 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
18 VDC
3.6 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133560000
RELAY GEN PURPOSE 3PDT 10A 220V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
220VDC
10 A
250VAC - Max
7.6 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
165 VDC
33 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133440000
RELAY GEN PURPOSE 3PDT 10A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
110VDC
10 A
250VAC - Max
15 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
82.5 VDC
16.5 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133810000
RELAY GEN PURPOSE 3PDT 10A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
3PDT (3 Form C)
Plug In, 11 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
24VAC
10 A
250VAC - Max
130 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
19.2 VAC
7.2 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133390000
RELAY GEN PURPOSE DPDT 10A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
110VDC
10 A
250VAC - Max
15 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
82.5 VDC
16.5 VDC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133800000
RELAY GEN PURPOSE DPDT 10A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
230VAC
10 A
250VAC - Max
14.9 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
184 VAC
69 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA
1133780000
RELAY GEN PURPOSE DPDT 10A 115V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
DPDT (2 Form C)
Plug In, 8 Pin (Octal)
-25°C ~ 55°C
cURus
DRR
115VAC
10 A
250VAC - Max
29.8 mA
Non Latching
Lighted Indicator, Mechanical Indicator
-
-
92 VAC
34.5 VAC
30 ms
20 ms
Silver Cadmium Oxide (AgCdO)
General Purpose
2500VA

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.