AHN Series, Power Relays, Over 2 Amps

Results:
102
Manufacturer
Series
Must Release Voltage
Coil Current
Coil Voltage
Must Operate Voltage
Features
Contact Form
Operating Temperature
Termination Style
Contact Rating (Current)
Load - Max Switching
Mounting Type
Contact Material
Release Time
Switching Voltage
Approval Agency
Seal Rating
Relay Type
Coil Insulation
Operate Time
Coil Type
Results remaining102
Applied Filters:
AHN
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeContact FormTermination StyleApproval AgencySeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max Switching
AHN211Y2
RELAY GEN PURPOSE DPDT 5A 240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
240VAC
5 A
250VAC, 30VDC - Max
4.1 mA
Non Latching
-
-
192 VAC
72 VAC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22205
RELAY GEN PURPOSE DPDT 5A 5V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
5VDC
5 A
250VAC, 30VDC - Max
106.4 mA
Non Latching
-
-
3.5 VDC
0.5 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22224
RELAY GEN PURPOSE DPDT 5A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
24VDC
5 A
250VAC, 30VDC - Max
22 mA
Non Latching
-
-
16.8 VDC
2.4 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22305
RELAY GEN PURPOSE DPDT 5A 5V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode, Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
5VDC
5 A
250VAC, 30VDC - Max
106.4 mA
Non Latching
-
-
3.5 VDC
0.5 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22312
RELAY GEN PURPOSE DPDT 5A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode, Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
12VDC
5 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.2 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22324
RELAY GEN PURPOSE DPDT 5A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode, Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
24VDC
5 A
250VAC, 30VDC - Max
22 mA
Non Latching
-
-
16.8 VDC
2.4 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22112
RELAY GEN PURPOSE DPDT 5A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
12VDC
5 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.2 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22212N
RELAY GEN PURPOSE DPDT 5A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
12VDC
5 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.8 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22112N
RELAY GEN PURPOSE DPDT 5A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
12VDC
5 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.2 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN220X1N
RELAY GEN PURPOSE DPDT 5A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
110VDC
5 A
250VAC, 30VDC - Max
4.8 mA
Non Latching
-
-
77 VDC
16.5 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22306N
RELAY GEN PURPOSE DPDT 5A 6V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode, Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
6VDC
5 A
250VAC, 30VDC - Max
88.2 mA
Non Latching
-
-
4.2 VDC
0.6 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN222X1N
RELAY GEN PURPOSE DPDT 5A 110V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
110VDC
5 A
250VAC, 30VDC - Max
4.8 mA
Non Latching
-
-
77 VDC
16.5 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN210X1
RELAY GEN PURPOSE DPDT 5A 120V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
120VAC
5 A
250VAC, 30VDC - Max
9.7 mA
Non Latching
-
-
96 VAC
36 VAC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22312N
RELAY GEN PURPOSE DPDT 5A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode, Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
12VDC
5 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.2 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN22005N
RELAY GEN PURPOSE DPDT 5A 5V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
5VDC
5 A
250VAC, 30VDC - Max
106.4 mA
Non Latching
-
-
3.5 VDC
0.75 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN12124
RELAY 1 FORM C DC PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Diode
-40°C ~ 70°C
Socketable
SPDT (1 Form C)
Plug In
cURus, VDE
AHN
24VDC
16 A
250VAC, 30VDC - Max
22 mA
Non Latching
-
-
16.8 VDC
3.6 VDC
15 ms
20 ms
Silver Nickel (AgNi)
General Purpose
4000VA, 480W
AHN111X0
RELAY 1 FORM C AC PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
-40°C ~ 70°C
Socketable
SPDT (1 Form C)
Plug In
cURus, VDE
AHN
110VAC
16 A
250VAC, 30VDC - Max
10.6 mA
Non Latching
-
-
70 VDC
15 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
4000VA, 480W
AHN211Y0N
RELAY 2 FORM C AC PLUG-IN 200/22
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Lighted Indicator
-40°C ~ 70°C
Socketable
DPDT (2 Form C)
Plug In
cURus, VDE
AHN
220VAC
5 A
250VAC, 30VDC - Max
5.3 mA
Non Latching
-
-
176 VAC
66 VAC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
1250VA, 150W
AHN12012
RELAY GEN PURPOSE SPDT 16A 12V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
Socketable
SPDT (1 Form C)
Plug In
cURus, VDE
AHN
12VDC
16 A
250VAC, 30VDC - Max
44.4 mA
Non Latching
-
-
8.4 VDC
1.2 VDC
15 ms
5 ms
Silver Nickel (AgNi)
General Purpose
4000VA, 480W
AHN110Y2
RELAY 1 FORM C AC PLUG-IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
Socketable
SPDT (1 Form C)
Plug In
cURus, VDE
AHN
240VAC
16 A
250VAC, 30VDC - Max
4.1 mA
Non Latching
-
-
192 VAC
72 VAC
15 ms
5 ms
Silver Tin Oxide (AgSnO)
General Purpose
4000VA, 480W

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.