288 Series, Power Relays, Over 2 Amps

Results:
13
Manufacturer
Series
Coil Current
Operate Time
Release Time
Contact Form
Operating Temperature
Coil Voltage
Contact Rating (Current)
Load - Max Switching
Switching Voltage
Termination Style
Contact Material
Approval Agency
Mounting Type
Must Release Voltage
Seal Rating
Relay Type
Coil Insulation
Must Operate Voltage
Features
Coil Type
Results remaining13
Applied Filters:
288
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeTermination StyleContact FormApproval AgencySeriesCoil VoltageContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeContact MaterialRelay TypeLoad - Max Switching
288-508
RELAY GEN PURPOSE SPDT 6A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
SPDT (1 Form C)
EAC
288
230VAC
6 A
250VAC - Max
6.1 mA
Non Latching
-
-
-
-
9 ms
3 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-437
RELAY GEN PURPOSE DPDT 5A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
Screw Terminal
DPDT (2 Form C)
EAC
288
24VDC
5 A
250VAC - Max
36 mA
Non Latching
-
-
-
-
15 ms
12 ms
Silver Nickel (AgNi)
General Purpose
1250VA
288-368
RELAY GEN PURPOSE SPST 5A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Spring Terminal
SPST-NC (1 Form B)
EAC
288
24VDC
5 A
250VAC - Max
20 mA
Non Latching
-
-
-
-
4 ms
6 ms
Silver Nickel (AgNi)
General Purpose
1250VA
288-504
RELAY GEN PURPOSE SPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
SPDT (1 Form C)
EAC
288
24VAC/DC
6 A
250VAC - Max
21.8 mA
Non Latching
-
-
-
-
9 ms
3 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-418
RELAY GEN PURPOSE 8PST 6A 230V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40° ~ 70°C
DIN Rail
Screw Terminal
8PST-4NO/4NC (4 Form A, 4 Form B)
EAC
288
230VAC/DC
6 A
250VAC - Max
14 mA
Non Latching
-
-
-
-
18 ms
21 ms
Silver Tin Oxide (AgSnO)
General Purpose
1500VA
288-304
RELAY GEN PURPOSE SPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
SPDT (1 Form C)
EAC
288
24VDC
6 A
250VAC - Max
21.8 mA
Non Latching
-
-
-
-
9 ms
3 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-312
RELAY GEN PURPOSE DPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
DPDT (2 Form C)
EAC
288
24VDC
6 A
250VAC - Max
21.8 mA
Non Latching
-
-
-
-
8 ms
3 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-512
RELAY GEN PURPOSE DPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 50°C
DIN Rail
Spring Terminal
DPDT (2 Form C)
EAC
288
24VAC/DC
6 A
250VAC - Max
21.8 mA
Non Latching
-
-
-
-
8 ms
3 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-414
RELAY GEN PURPOSE 8PST 6A 240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40° ~ 70°C
DIN Rail
Screw Terminal
8PST-4NO/4NC (4 Form A, 4 Form B)
EAC
288
24VAC/DC
6 A
250VAC - Max
26 mA
Non Latching
-
-
-
-
18 ms
21 ms
Silver Tin Oxide (AgSnO)
General Purpose
1500VA
288-320
RELAY GEN PURPOSE 16A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Spring Terminal
SPST-NO (1 Form A)
EAC
288
24VDC
16 A
400VAC - Max
21.8 mA
Non Latching
-
-
-
-
8 ms
2 ms
Silver Tin Oxide (AgSnO)
General Purpose
6400VA
288-380
RELAY GEN PURPOSE SPDT 6A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
SPDT (1 Form C)
EAC
288
24VDC
6 A
250VAC - Max
51 mA
Non Latching
-
-
-
-
10 ms
10 ms
Silver Nickel (AgNi)
General Purpose
1500VA
288-564
RELAY GEN PURPOSE SPST 5A 240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Screw Terminal
SPST-NO (1 Form A)
EAC
288
24VAC/DC
5 A
250VAC - Max
20 mA
Non Latching
-
-
-
-
4 ms
6 ms
Silver Nickel (AgNi)
General Purpose
1250VA
288-364
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
Spring Terminal
SPST-NO (1 Form A)
EAC
288
24VDC
5 A
250VAC - Max
20 mA
Non Latching
-
-
-
-
4 ms
6 ms
Silver Nickel (AgNi)
General Purpose
1250VA

About  Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.