ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeFeaturesApproval AgencyTermination StyleSeriesCoil VoltageContact FormContact Rating (Current)Switching VoltageCoil CurrentCoil TypeSeal RatingCoil InsulationMust Operate VoltageMust Release VoltageOperate TimeRelease TimeOperating TemperatureContact MaterialRelay TypeLoad - Max Switching
18836C200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
CSA, UR
Quick Connect - 0.250" (6.3mm)
188
24VDC
SPDT (DB/DM) (1 Form Z)
30 A
277VAC, 28VDC - Max
51.1 mA
Non Latching
-
Class B
18 VDC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18885T200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
-
CSA, UR
PC Pin
188
120VAC
SPST-NC (DB) (1 Form Y)
30 A
277VAC, 28VDC - Max
70.6 mA
Non Latching
-
Class B
102 VAC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18885B200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
-
CSA, UR
PC Pin
188
12VDC
SPST-NC (DB) (1 Form Y)
30 A
277VAC, 28VDC - Max
100 mA
Non Latching
-
Class B
9 VDC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18824C200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
CSA, UR
Quick Connect - 0.250" (6.3mm)
188
24VDC
SPST-NO (DM) (1 Form X)
30 A
277VAC, 28VDC - Max
51.1 mA
Non Latching
-
Class B
18 VDC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18834B200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
CSA, UR
Quick Connect - 0.250" (6.3mm)
188
12VDC
SPST-NO (DM) (1 Form X)
30 A
277VAC, 28VDC - Max
100 mA
Non Latching
-
Class B
9 VDC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18836T200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
CSA, UR
Quick Connect - 0.250" (6.3mm)
188
120VAC
SPDT (DB/DM) (1 Form Z)
30 A
277VAC, 28VDC - Max
70.6 mA
Non Latching
-
Class B
102 VAC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18884T200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
-
CSA, UR
PC Pin
188
120VAC
SPST-NO (DM) (1 Form X)
30 A
277VAC, 28VDC - Max
70.6 mA
Non Latching
-
Class B
102 VAC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W
18886B200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
-
CSA, UR
PC Pin
188
12VDC
SPDT (DB/DM) (1 Form Z)
30 A
277VAC, 28VDC - Max
100 mA
Non Latching
-
Class B
9 VDC
-
20 ms
10 ms
-45°C ~ 70°C
Silver Cadmium Oxide (AgCdO)
General Purpose
8310VA, 840W

Power Relays, Over 2 Amps

Power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads using a smaller control signal. These relays are specifically engineered to handle higher current levels, providing a reliable and efficient solution for applications requiring the control of significant power. The contacts of power relays over 2 Amps are rated to handle various current levels, ranging from 2 A to 750 A. This wide range of ratings allows for flexibility in selecting a relay that matches the specific current requirements of the load being controlled. The available ratings include 2 A, 3 A, 3.5 A, 4 A, 5 A, 6 A, 7 A, 7.5 A, 8 A, 8.5 A, 9 A, 10 A, 11 A, 12 A, 14 A, 15 A, 16 A, 18 A, 20 A, 21 A, 23 A, 25 A, 26 A, 30 A, 31 A, 32 A, 33 A, 35 A, 40 A, 48 A, 50 A, 60 A, 90 A, 100 A, 120 A, 150 A, 200 A, 400 A, and 750 A. These power relays consist of an electromagnet and a set of contacts. When the control signal is applied to the electromagnet coil, it generates a magnetic field that attracts or releases the contacts, allowing the larger load current to flow or be interrupted accordingly. This mechanism enables the safe and reliable control of high-power devices such as motors, heaters, lighting systems, and other industrial equipment. Power relays over 2 Amps are commonly used in various industries, including manufacturing, energy, transportation, and telecommunications. They provide a robust and dependable solution for switching heavy loads, ensuring efficient operation and protection of electrical systems. It's important to select the appropriate power relay with a current rating that matches or exceeds the load requirements to ensure safe and reliable operation. Additionally, factors such as coil voltage, contact configuration (such as normally open or normally closed), and mounting options should be considered when choosing a power relay for a specific application. In summary, power relays over 2 Amps are electromechanical devices designed to control the switching of large electrical loads. They offer a wide range of current ratings, accommodating various load requirements. These relays are widely used in industrial applications where the control of high-power devices is necessary. By providing a reliable and efficient means of controlling significant electrical loads, power relays contribute to the smooth and safe operation of diverse systems and equipment.