FMBC NEO Series, Power Line Filter Modules

Results:
18
Manufacturer
Series
Current
Inductance
Operating Temperature
Configuration
Applications
Frequency - Operating
Termination Style
Approval Agency
Mounting Type
Filter Type
Voltage - Rated AC (Phase to Ground/Neutral)
Voltage - Rated AC
Voltage - Rated AC (Phase to Phase)
Voltage - Rated DC
Results remaining18
Applied Filters:
FMBC NEO
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApplicationsOperating TemperatureTermination StyleCurrentSeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACFrequency - OperatingApproval AgencyInductanceVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)
FMBC-A91V-J810
LINE FILTER 480/520VAC 180A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
180 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 400µH, L2 - 31µH
-
-
FMBC-A91Q-3012
LINE FILTER 480/520VAC 30A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
30 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.9mH, L2 - 10µH
-
-
FMBC-A91Q-3010
LINE FILTER 480/520VAC 30A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
30 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.9mH, L2 - 10µH
-
-
FMBC-A91R-4210
LINE FILTER 480/520VAC 42A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
42 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.3mH, L2 - 10µH
-
-
FMBC-A91U-0712
LINE FILTER 480/520VAC 7A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
7 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 2.7mH, L2 - 5µH
-
-
FMBC-A91R-4212
LINE FILTER 480/520VAC 42A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
42 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.3mH, L2 - 10µH
-
-
FMBC-A91S-5512
LINE FILTER 480/520VAC 55A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
55 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.8mH, L2 - 13µH
-
-
FMBC-A91S-5510
LINE FILTER 480/520VAC 55A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
55 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.8mH, L2 - 13µH
-
-
FMBC-A91V-J812
LINE FILTER 480/520VAC 180A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
180 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 400µH, L2 - 31µH
-
-
FMBC-A91C-1610
LINE FILTER 480/520VAC 16A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
16 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.9mH, L2 - 10µH
-
-
FMBC-A91G-J312
LINE FILTER 480/520VAC 130A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
130 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 700µH, L2 - 26µH
-
-
FMBC-A91G-J310
LINE FILTER 480/520VAC 130A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
130 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 700µH, L2 - 26µH
-
-
FMBC-A91C-1612
LINE FILTER 480/520VAC 16A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
16 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.9mH, L2 - 10µH
-
-
FMBC-A91G-J012
LINE FILTER 480/520VAC 100A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
100 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.2mH, L2 - 13µH
-
-
FMBC-A91G-J010
LINE FILTER 480/520VAC 100A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
100 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.2mH, L2 - 13µH
-
-
FMBC-A91F-7512
LINE FILTER 480/520VAC 75A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
75 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.2mH, L2 - 13µH
-
-
FMBC-A91F-7510
LINE FILTER 480/520VAC 75A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
75 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 1.2mH, L2 - 13µH
-
-
FMBC-A91U-0710
LINE FILTER 480/520VAC 7A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-25°C ~ 100°C
Terminal Block
7 A
FMBC NEO
Three Phase (Delta)
Two Stage
-
480V, 520V
50/60Hz
cURus, ENEC, VDE
L1 - 2.7mH, L2 - 5µH
-
-

About  Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.