FLLE2-P Series, Power Line Filter Modules

Results:
36
Manufacturer
Series
Current
Inductance
Termination Style
Applications
Operating Temperature
Configuration
Frequency - Operating
Approval Agency
Mounting Type
Filter Type
Voltage - Rated AC (Phase to Ground/Neutral)
Voltage - Rated AC
Voltage - Rated AC (Phase to Phase)
Voltage - Rated DC
Results remaining36
Applied Filters:
FLLE2-P
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApplicationsTermination StyleOperating TemperatureCurrentInductanceApproval AgencySeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACFrequency - OperatingVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)
FLLE2006APDB
EMI FILTER, 300VDC, 6A, FAST-ON,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Quick Connect
-25°C ~ 100°C
6 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2010APMB
EMI FILTER, 300VDC, 10A, FAST-ON
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Quick Connect
-25°C ~ 100°C
10 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2010APMD
EMI FILTER, 300VDC, 10A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
10 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2006APMD
EMI FILTER, 300VDC, 6A, FLEX WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
6 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2006APMB
EMI FILTER, 300VDC, 6A, FAST-ON,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Quick Connect
-25°C ~ 100°C
6 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2003APMB
EMI FILTER, 300VDC, 3A, FAST-ON,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Quick Connect
-25°C ~ 100°C
3 A
2.5mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2006APDD
EMI FILTER, 300VDC, 6A, FLEX WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
6 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2003APMD
EMI FILTER, 300VDC, 3A, FLEX WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
3 A
2.5mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2020APMI
EMI FILTER, 300VDC, 20A, THREAD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Threaded Post (M4)
-25°C ~ 100°C
20 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2025APMD
EMI FILTER, 300VDC, 25A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
25 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2032APMD
EMI FILTER, 300VDC, 32A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
32 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2010APDD
EMI FILTER, 300VDC, 10A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
10 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2025APDD
EMI FILTER, 300VDC, 25A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
25 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2032APDD
EMI FILTER, 300VDC, 32A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
32 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2010APDB
EMI FILTER, 300VDC, 10A, FAST-ON
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Quick Connect
-25°C ~ 100°C
10 A
1mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2013APMD
EMI FILTER, 300VDC, 13A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
Wire Leads
-25°C ~ 100°C
13 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2013APDD
EMI FILTER, 300VDC, 13A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
13 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2001APDD
EMI FILTER, 300VDC, 1A, FLEX WIR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
1 A
12mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2020APDD
EMI FILTER, 300VDC, 20A, FLEX WI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Wire Leads
-25°C ~ 100°C
20 A
800µH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-
FLLE2003APDB
EMI FILTER, 300VDC, 3A, FAST-ON,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
Quick Connect
-25°C ~ 100°C
3 A
2.5mH
ENEC, UR
FLLE2-P
Single Phase
Single Stage
300V
300V
50/60Hz
-
-

About  Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.