AMI-29 Series, Power Line Filter Modules

Results:
60
Manufacturer
Series
Current
Inductance
Termination Style
Applications
Operating Temperature
Configuration
Frequency - Operating
Approval Agency
Mounting Type
Filter Type
Voltage - Rated AC (Phase to Ground/Neutral)
Voltage - Rated AC
Voltage - Rated AC (Phase to Phase)
Voltage - Rated DC
Results remaining60
Applied Filters:
AMI-29
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApproval AgencyTermination StyleCurrentOperating TemperatureApplicationsSeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACFrequency - OperatingInductanceVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)
AMI-29B-1-3
LINE FILTER 110/250VAC 1A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
1 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
40mH
-
-
AMI-29A-3-1
LINE FILTER 110/250VAC 3A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
3 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29B-16-3
LINE FILTER 110/250VAC 16A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect, Wire Leads
16 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
8mH
-
-
AMI-29B-3-1
LINE FILTER 110/250VAC 3A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
3 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29B-6-1
LINE FILTER 110/250VAC 6A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
6 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
16mH
-
-
AMI-29B-10-1
LINE FILTER 110/250VAC 10A CHASS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
10 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
16mH
-
-
AMI-29A-12-3
LINE FILTER 110/250VAC 12A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
12 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
8mH
-
-
AMI-29B-3-3
LINE FILTER 110/250VAC 3A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
3 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29A-30-6
LINE FILTER 110/250VAC 30A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Threaded Post (M4)
30 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
3mH
-
-
AMI-29B-30-6
LINE FILTER 110/250VAC 30A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Threaded Post (M4)
30 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
3mH
-
-
AMI-29A-16-3
LINE FILTER 110/250VAC 16A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect, Wire Leads
16 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
8mH
-
-
AMI-29-20-3
LINE FILTER 110/250VAC 20A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect, Threaded Post (M4)
20 A
-25°C ~ 100°C
General Purpose
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
5.4mH
-
-
AMI-29A-20-6
LINE FILTER 110/250VAC 20A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect, Threaded Post (M4)
20 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
5.4mH
-
-
AMI-29-1-3
LINE FILTER 110/250VAC 1A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
1 A
-25°C ~ 100°C
General Purpose
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
40mH
-
-
AMI-29A-4-3
LINE FILTER 110/250VAC 4A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
4 A
-25°C ~ 100°C
Safety
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29B-4-3
LINE FILTER 110/250VAC 4A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
4 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29-1-1
LINE FILTER 110/250VAC 1A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
1 A
-25°C ~ 100°C
General Purpose
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
40mH
-
-
AMI-29B-1-1
FILTER MULTI-STAGE HI PERFORM 1A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
1 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
40mH
-
-
AMI-29-3-1
LINE FILTER 110/250VAC 3A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
3 A
-25°C ~ 100°C
General Purpose
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-
AMI-29B-4-1
LINE FILTER 110/250VAC 4A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CE, cURus
Quick Connect
4 A
-25°C ~ 100°C
Medical
AMI-29
Single Phase
Two Stage
-
250V
DC ~ 400Hz
28mH
-
-

About  Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.