5124 Series, Power Line Filter Modules

Results:
24
Manufacturer
Series
Inductance
Current
Applications
Operating Temperature
Configuration
Frequency - Operating
Termination Style
Approval Agency
Mounting Type
Filter Type
Voltage - Rated AC (Phase to Ground/Neutral)
Voltage - Rated AC
Voltage - Rated AC (Phase to Phase)
Voltage - Rated DC
Results remaining24
Applied Filters:
5124
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApplicationsOperating TemperatureCurrentApproval AgencySeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACFrequency - OperatingTermination StyleInductanceVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)
3-130-964
5124 CONNECTOR FILTER C14 6A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
6 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
4.7mH
-
-
3-130-935
5124 CONNECTOR FILTER C14 1A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
1 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
89mH
-
-
3-130-939
5124 CONNECTOR FILTER C14 10A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
10 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
1.5mH
-
-
3-130-967
5124 CONNECTOR FILTER C14 1A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
1 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
89mH
-
-
3-130-971
5124 CONNECTOR FILTER C14 10A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
10 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
1.5mH
-
-
3-130-969
5124 CONNECTOR FILTER C14 4A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
4 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
8.7mH
-
-
3-130-936
5124 CONNECTOR FILTER C14 2A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
2 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
33mH
-
-
3-130-968
5124 CONNECTOR FILTER C14 2A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
2 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
33mH
-
-
3-130-940
5124 CONNECTOR FILTER C14 15A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
15 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
600µH
-
-
3-130-966
5124 CONNECTOR FILTER C14 15A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
15 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
600µH
-
-
3-130-953
5124 CONNECTOR FILTER C14 2A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
2 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
33mH
-
-
3-130-963
5124 CONNECTOR FILTER C14 4A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
4 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
8.7mH
-
-
3-130-941
5124 CONNECTOR FILTER C14 1A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
1 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
89mH
-
-
3-130-965
5124 CONNECTOR FILTER C14 10A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
10 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
1.5mH
-
-
3-130-962
5124 CONNECTOR FILTER C14 2A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
2 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
33mH
-
-
3-130-954
5124 CONNECTOR FILTER C14 4A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
4 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
8.7mH
-
-
3-130-955
5124 CONNECTOR FILTER C14 6A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
6 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
4.7mH
-
-
3-130-956
5124 CONNECTOR FILTER C14 10A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
10 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
1.5mH
-
-
3-121-378
5124 CONNECTOR FILTER C14 15A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
15 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
600µH
-
-
3-121-370
5124 CONNECTOR FILTER C14 1A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
1 A
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
89mH
-
-

About  Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.