ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeOperating TemperatureTermination StyleCurrentApproval AgencySeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)Frequency - OperatingApplicationsInductance
6609974-4
LINE FILTER 12A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
12 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
6609070-2
LINE FILTER 12A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
12 A
UR
FCD
Three Phase (Delta)
Two Stage
-
-
277 V
480 V
50/60Hz
General Purpose
-
25FCD10
LINE FILTER 25A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
25 A
UR
FCD
Three Phase (Delta)
Two Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
6609974-5
LINE FILTER 16A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
16 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
36FCD10
LINE FILTER 36A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
36 A
UR
FCD
Three Phase (Delta)
Two Stage
-
-
277 V
480 V
50/60Hz
General Purpose
-
1-6609974-6
LINE FILTER 50A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
50 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609974-3
LINE FILTER 50A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
50 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609974-7
LINE FILTER 80A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
80 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609974-8
LINE FILTER 110A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
110 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
2-6609974-1
LINE FILTER 180A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
180 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
6FCD10
LINE FILTER 6A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
6 A
UR
FCD
Three Phase (Delta)
Two Stage
-
-
277 V
480 V
50/60Hz
General Purpose
-
6609070-7
LINE FILTER 80A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
80 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609974-1
LINE FILTER 36A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
36 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
6609070-8
FILTER 3PHASE EXTERNAL LINE 110A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block, Threaded Post (M10)
110 A
UL
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50 ~ 60Hz
Regenerative Motor Drive
-
3-6609974-3
LINE FILTER 150A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
150 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609070-2
LINE FILTER 230A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
230 A
UL
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
General Purpose
-
6609974-9
LINE FILTER 25A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
25 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
1-6609070-0
LINE FILTER 180A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
180 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
6609070-3
LINE FILTER 16A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
16 A
UR
FCD
Three Phase (Delta)
Two Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-
3-6609974-6
LINE FILTER 230A CHASSIS MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-10°C ~ 40°C
Terminal Block
230 A
UR
FCD
Three Phase (Delta)
Single Stage
-
-
277 V
480 V
50/60Hz
Regenerative Motor Drive
-

About  Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.