S62 Series, Photoelectric, Industrial

Results:
26
Manufacturer
Series
Sensing Distance
Response Time
Light Source
Output Configuration
Sensing Method
Cable Length
Connection Method
Adjustment Type
Operating Temperature
Ingress Protection
Voltage - Supply
Results remaining26
Applied Filters:
S62
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureVoltage - SupplyIngress ProtectionAdjustment TypeResponse TimeSensing MethodOutput ConfigurationLight SourceConnection MethodCable LengthSensing DistanceSeries
S62-PA-5-M15-NN
956201850 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
NPN - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 23.622" (60mm ~ 600mm)
S62
S62-PL-5-M11-NN
956214100 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
Adjustable
200µs
Background Suppression
NPN - Dark-ON/Light-ON
Red (645nm, 665nm)
Connector, M12
-
2.362" ~ 23.622" (60mm ~ 600mm)
S62
S62-PL-5-M01-PP
956211130 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
Adjustable
140µs
Background Suppression
PNP - Dark-ON/Light-ON
Red (645nm, 665nm)
Connector, M12
-
1.181" ~ 11.811" (30mm ~ 300mm)
S62
S62-PL-5-B01-NN
956214080 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
Adjustable
200µs
Retroreflective, Polarized
NPN - Dark-ON/Light-ON
Red (645nm, 665nm)
Connector, M12
-
11.811" ~ 787.402" (300mm ~ 20m)
S62
S62-PA-5-M35-NN
956211080 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1.5ms
Background Suppression
NPN - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
7.87" ~ 78.74" (200mm ~ 2000mm)
S62
S62-PA-2-M31-PP
956211050 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1.5ms
Background Suppression
PNP - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
7.87" ~ 78.74" (200mm ~ 2000mm)
S62
S62-PA-5-M31-NN
956214060 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1.5ms
Background Suppression
NPN - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
7.87" ~ 78.74" (200mm ~ 2000mm)
S62
S62-PA-5-M25-NN
956201930 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1ms
Background Suppression
NPN - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 47.244" (60mm ~ 1.2m)
S62
S62-PA-2-M21-PP
956201940 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1ms
Background Suppression
PNP - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 47.244" (60mm ~ 1.2m)
S62
S62-PA-5-M21-PP
956201900 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
1ms
Background Suppression
PNP - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 47.244" (60mm ~ 1.2m)
S62
S62-PA-5-C01-PP
PHOTO SENSOR DIFFUSE BEAM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Diffuse
PNP - Dark-ON/Light-ON
Red (640nm)
Cable
78.74" (2m)
0" ~ 35.433" (0mm ~ 900mm)
S62
S62-PA-5-M01-NN
956214000 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
NPN - Dark-ON/Light-ON
Red (660nm)
Cable
78.74" (2m)
1.181" ~ 11.811" (30mm ~ 300mm)
S62
S62-PA-5-M01-PP
956201831 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
Adjustable
500µs
Background Suppression
PNP - Dark-ON/Light-ON
Red (660nm)
Connector, M12
-
1.181" ~ 11.811" (30mm ~ 300mm)
S62
S62-PA-5-M05-PP
956201820 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
PNP - Dark-ON/Light-ON
Red (660nm)
Cable
78.74" (2m)
1.181" ~ 11.811" (30mm ~ 300mm)
S62
S62-PA-2-M11-PP
956201890 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
PNP - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 23.622" (60mm ~ 600mm)
S62
S62-PA-5-M05-NN
956201800 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
NPN - Dark-ON/Light-ON
Red (660nm)
Cable
78.74" (2m)
1.181" ~ 11.811" (30mm ~ 300mm)
S62
S62-PA-5-M11-NN
956214020 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Background Suppression
NPN - Dark-ON/Light-ON
Infrared (880nm)
Cable
78.74" (2m)
2.362" ~ 23.622" (60mm ~ 600mm)
S62
S62-PA-5-M11-PP
956201880 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
Adjustable
500µs
Background Suppression
PNP - Dark-ON/Light-ON
Infrared (880nm)
Connector, M12
-
2.362" ~ 23.622" (60mm ~ 600mm)
S62
S62-PA-5-B01-PP
956211000 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Retroreflective, Polarized
PNP - Dark-ON/Light-ON
Red (640nm)
Cable
78.74" (2m)
0" ~ 393.701" (0m ~ 10m)
S62
S62-PA-2-B01-PP
956211010 SENSOR BLOCK-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 55°C
10V ~ 30V
IP67
-
500µs
Retroreflective, Polarized
PNP - Dark-ON/Light-ON
Red (640nm)
Cable
78.74" (2m)
0" ~ 393.701" (0m ~ 10m)
S62

About  Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.